POWER BACK DOOR CLOSER SWITCH INSPECTION

PROCEDURE


  1. INSPECT DOOR CONTROL SWITCH ASSEMBLY


    1. Check the operation of the door control switch assembly.


      1. A00YXABC01
        *a

        Component without harness connected

        (Door Control Switch Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        1 (CLS) - 2 (E) Door control switch assembly not pushed 10 kΩ or higher
        Door control switch assembly pushed Below 1 Ω

        If the result is not as specified, replace the door control switch.