DESCRIPTION
When the theft deterrent system is switched from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) transmits a signal to cause the horn to sound at intervals of 0.4 seconds.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
When replacing the main body ECU (multiplex network body ECU), make sure to replace it with a new one.
PROCEDURE
CHECK HORNS OPERATION
Press the horn switch and check if the horns sound.
| Result | |||
|---|---|---|---|
|
| Horns do not sound |
|
GO TO HORN SYSTEM Click here |
| Horns sound |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | HORN |
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | ||||
|---|---|---|---|---|
|
| OK (for LHD) |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here |
| OK (for RHD) |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here |
| NG |
|
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |