LIN COMMUNICATION SYSTEM, Diagnostic DTC:B1249

DTC Code DTC Name
B1249 Double Locking ECU Communication Stop

DESCRIPTION

DTC B1249 is stored when communication between the double lock door control relay assembly and main body ECU (multiplex network body ECU) stops for more than 10 seconds.

DTC No. Detection Item DTC Detection Condition Trouble Area
B1249 Double Locking ECU Communication Stop No communication from the double lock door control relay assembly for more than 10 seconds.
  • Double lock door control relay assembly

  • Main body ECU (multiplex network body ECU)

  • Harness or connector

  • Instrument panel junction block assembly

WIRING DIAGRAM

A01QUPQE02

CAUTION / NOTICE / HINT

Note


  • When using the GTS with the ignition switch off to troubleshoot:

    Connect the GTS to the vehicle, and turn a courtesy light switch on and off at 1.5 second intervals until communication between the GTS and vehicle begins.

  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

  • When replacing the main body ECU (multiplex network body ECU), make sure to replace it with a new one.

Tech Tips

When the communication between the double lock door control relay and main body ECU (multiplex network body ECU) stops, DTC B2325 is also stored.

PROCEDURE


  1. CLEAR DTC


    1. Clear the DTCs.

      Click here


      Body Electrical > Main Body > Clear DTCs
      Result
      Proceed to
      NEXT

    NEXT
  2. CHECK FOR DTC


    1. Check for DTCs.

      Click here


      Body Electrical > Main Body > Trouble Codes
      Result
      Proceed to
      DTC B1249 is output
      DTC B1249 is not output

    DTC B1249 is not output
    DTC B1249 is output
  3. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU [MULTIPLEX NETWORK BODY ECU] - DOUBLE LOCK DOOR CONTROL RELAY ASSEMBLY)


    1. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

      for LHD: Click here

      for RHD: Click here

    2. Disconnect the G66 double lock door control relay assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-16 (LIN2) - G66-9 (MPX1) Always Below 1 Ω
      A-16 (LIN2) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (DOUBLE LOCK DOOR CONTROL RELAY ASSEMBLY - BATTERY AND BODY GROUND)


    1. A01QQ3SC02
      *a

      Front view of wire harness connector

      (to Double Lock Door Control Relay Assembly)

      Disconnect the G66 double lock door control relay assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G66-14 (GND) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      G66-1 (+B) - Body ground Always 11 to 14 V
      G66-7 (CPUB) - Body ground Always 11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  5. REPLACE DOUBLE LOCK DOOR CONTROL RELAY ASSEMBLY


    1. Temporarily replace the double lock door control relay assembly with a new or normally functioning one.

      Click here

    2. Clear the DTCs.

      Click here


      Body Electrical > Main Body > Clear DTCs
      Result
      Proceed to
      NEXT

    NEXT
  6. CHECK FOR DTC


    1. Check for DTCs.

      Click here


      Body Electrical > Main Body > Trouble Codes
      Result
      Proceed to
      DTC B1249 is not output
      DTC B1249 is output (for LHD)
      DTC B1249 is output (for RHD)

    DTC B1249 is not output
    DTC B1249 is output (for LHD)
    DTC B1249 is output (for RHD)
  7. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - DOUBLE LOCK DOOR CONTROL RELAY ASSEMBLY)


    1. Disconnect the 3D instrument panel junction block assembly connector.

    2. Disconnect the G66 double lock door control relay assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3D-54 - G66-9 (MPX1) Always Below 1 Ω
      3D-54 - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK (for LHD)
      OK (for RHD)
      NG

    OK (for LHD)
    OK (for RHD)
    NG