CHARGING SYSTEM PRECAUTION

SST
A00YX4W 09820-63021 Alternator Pulley Wrench Set

  1. PRECAUTION


    1. Check that the battery cables are connected to the correct terminals.

    2. Disconnect the battery cables when a quick charge is given to the battery.

    3. Do not perform tests with a high voltage insulation resistance tester.

    4. Never disconnect the battery while the engine is running.

    5. Check that the charging cable is securely connected to terminal B of the generator and the fuse box.

    6. Do not check whether the generator generates current or not while terminal F is connected to the other terminals.

  2. IGNITION SWITCH EXPRESSIONS


    1. The type of ignition switch used on this model differs depending on the specifications of the vehicle. The expressions listed in the table below are used in this section.

      Expression Ignition Switch (Position) Engine Switch (Condition)
      Ignition Switch off LOCK Off (Lock)
      Ignition Switch ACC ACC On (ACC)
      Ignition Switch ON ON On (IG)
      Engine Start START On (Start)