GENERATOR(for 150 A Type) REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE FAN AND GENERATOR V BELT

    Click here

  4. REMOVE WIRE HARNESS CLAMP BRACKET

    A01V9P8

    1. Detach the wire harness clamp from the clamp bracket.

    2. Remove the bolt and clamp bracket.

  5. REMOVE GENERATOR ASSEMBLY


    1. A01VAWF

      Disconnect the generator connector.

    2. Remove the terminal cap.

    3. Remove the nut and disconnect the generator wire.

    4. Remove the bolt and wire harness clamp bracket.

    5. A01VAYE

      Remove the 2 bolts and generator assembly.