CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM, Diagnostic DTC:P2769, P2770

DTC Code DTC Name
P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)
P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

DESCRIPTION

Based on the signal received by the shift solenoid valve SL, the ECM uses the shift solenoid valve SLU to control the lock-up clutch pressure.

If there is an open or short in the shift solenoid valve SL circuit, the ECM stops sending current to the defective shift solenoid valve.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other


  1. Lock-up is operating.

  2. A short in the shift solenoid valve SL circuit is detected.

  3. Detected 1 time or more consecutively

  4. 1-trip detection logic


  • Harness or connector

  • Continuously variable transaxle assembly (Shift solenoid valve SL)

  • ECM

Comes on DTC stored
P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other


  1. Lock-up is operating.

  2. An open in the shift solenoid valve SL circuit is detected.

  3. Detected 1 time or more consecutively

  4. 1-trip detection logic


  • Harness or connector

  • Continuously variable transaxle assembly (Shift solenoid valve SL)

  • ECM

Comes on DTC stored

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SL circuit. If there is an open or short in the shift solenoid valve SL circuit, the ECM detects the problem, illuminates the MIL and stores a DTC.

WIRING DIAGRAM

A01QQ10E40
*1 Shift Solenoid Valve SL
*2 Continuously Variable Transaxle Assembly (Transmission Wire)

CAUTION / NOTICE / HINT

Note


  • Perform initialization when parts related to the continuously variable transaxle are replaced.

    Click here

  • Check that no DTCs are stored after performing initialization.

    Click here

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)


    1. A01QPFJC10
      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      12 (SL) - Body ground 20°C (68°F) 11 to 15 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. A01QPVYC05
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B93-67 (SL) - Body ground 20°C (68°F) 11 to 15 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. REPLACE ECM


    1. Replace the ECM.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  4. REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY


    1. Replace the continuously variable transaxle assembly.

      Click here

      Result
      Proceed to
      NEXT

    NEXT