CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM, Diagnostic DTC:P2769, P2770

DTC Code DTC Name
P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)
P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

DESCRIPTION

The ECM turns shift solenoid valve SL on or off to control the oil pressure applied to the lock-up relay valve and turns lock-up on or off.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other


  1. Lock-up is operating.

  2. There is a short circuit in the shift solenoid valve SL circuit.

  3. Detected 2 times or more consecutively

  4. 1 trip detection logic


  • Short in shift solenoid valve SL circuit

  • Continuously variable transaxle assembly

  • ECM

Comes on DTC stored
P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other


  1. Lock-up is operating.

  2. There is an open circuit in the shift solenoid valve SL circuit.

  3. Detected 2 times or more consecutively

  4. 1 trip detection logic


  • Open in shift solenoid valve SL circuit

  • Continuously variable transaxle assembly

  • ECM

Comes on DTC stored

MONITOR DESCRIPTION

These DTCs indicate an open or short circuit in the shift solenoid valve SL circuit. When there is an open or short circuit in the shift solenoid valve SL circuit, the ECM detects the problem, illuminates the MIL and stores the DTC.

WIRING DIAGRAM

A01QSZFE10
*a Shift Solenoid Valve SL
*b Transmission Wire (Continuously Variable Transaxle Assembly)

CAUTION / NOTICE / HINT

Note


  • Perform initialization when parts related to the continuously variable transaxle are replaced.

    Click here

  • Check that no DTCs are stored after performing initialization.

    Click here

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)


    1. A01QUP3C08
      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (SL) - Body ground 20°C (68°F) 11 to 15 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. A01QP1NC17
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B75-68 (SL) - Body ground 20°C (68°F) 11 to 15 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. REPLACE ECM


    1. Replace the ECM.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  4. REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY


    1. Replace the continuously variable transaxle assembly.

      Click here

      Result
      Proceed to
      NEXT

    NEXT