BACK-UP LIGHT SWITCH INSPECTION

PROCEDURE


  1. INSPECT BACK-UP LIGHT SWITCH ASSEMBLY


    1. A00YX9AC08
      *a

      Component without harness connected

      (Back-Up Light Switch Assembly)

      *b Push
      *c Release

      Measure the resistance according to the values in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 - 2 Pushed Below 1 Ω
      1 - 2 Released 10 kΩ or higher

      If the result is not as specified, replace the back-up light switch assembly.