INPUT SHAFT INSPECTION

PROCEDURE


  1. INSPECT INPUT SHAFT


    1. A00YR8Q

      Check the input shaft for wear and damage.

    2. Using a dial indicator, measure the input shaft runout.

      Maximum runout
      0.03 mm (0.00118 in.)

      If the runout is more than the maximum, replace the input shaft.

    3. A00YWM7E01

      Using a micrometer, measure the journal diameter at A and B on the input shaft.

      Standard Journal Diameter
      Measured Part Specified Condition
      Journal A 30.008 to 30.020 mm (1.1815 to 1.1818 in.)
      Journal B 32.002 to 32.018 mm (1.2600 to 1.2605 in.)

      If the diameter is not as specified, replace the input shaft.