AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

Refer to DTC P2714.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) An open or short is detected in the shift solenoid valve SLT circuit for 1 sec. or more while driving (1-trip detection logic).
  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • Wiring harness connector

  • ECM

Comes on DTC stored

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM

A01QQF0E24

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click here

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLT CIRCUIT)


    1. A01QP1NC05
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B77-15 (SLT+) - B77-14 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      B77-15 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
      B77-14 (SLT-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (WIRING HARNESS CONNECTOR - ECM)


    1. Disconnect the B78 wiring harness connector.

    2. Disconnect the B77 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B78-15 (SLT+) - B77-15 (SLT+) Always Below 1 Ω
      B78-7 (SLT-) - B77-14 (SLT-) Always Below 1 Ω
      B78-15 (SLT+) or B77-15 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
      B78-7 (SLT-) or B77-14 (SLT-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    1. A01QRY1C06
      *a

      Component without harness connected

      (Transmission Wire)

      Remove the wiring harness connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-12 (SLT+) - A-7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      A-12 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
      A-7 (SLT-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  4. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01QTPTC14
      *1 Shift Solenoid Valve SLT

      Remove shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise
      Result
      Proceed to
      OK
      NG

    OK
    NG