DESCRIPTION
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| C1428 | Motor Circuit Malfunction | With the motor relay and motor fail safe relay OFF, open or short in motor circuit continues for 2 seconds or more. | Brake actuator assembly (Motor circuit) |
CAUTION / NOTICE / HINT
Note
When replacing the skid control ECU (brake actuator assembly), perform zero point calibration.
PROCEDURE
CHECK HARNESS AND CONNECTOR (GND2 TERMINAL)
Turn the ignition switch off.
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
Disconnect the A80 skid control ECU (brake actuator assembly) connector.
| *a | Front view of wire harness connector (to Skid Control ECU [Brake Actuator Assembly]) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE BRAKE ACTUATOR ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (GND2 CIRCUIT) |