CRUISE CONTROL SYSTEM TC and CG Terminal Circuit

WIRING DIAGRAM

A01KD34E01

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (DLC3 - ECM AND BODY GROUND)


    1. for 1AD-FTV, 2AD-FHV, 2AD-CCo, 2AD-DPF


      1. Disconnect the A61 ECM connector.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        G14-13 (TC) - A61-26 (TC) Always Below 1 Ω
        G14-4 (CG) - Body ground Always Below 1 Ω
        G14-13 (TC) or A61-26 (TC) - Body ground Always 10 kΩ or higher
    2. for 2AR-FE, 3ZR-FAE, 3ZR-FE


      1. Disconnect the A62 ECM connector.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        G14-13 (TC) - A62-23 (TC) Always Below 1 Ω
        G14-4 (CG) - Body ground Always Below 1 Ω
        G14-13 (TC) or A62-23 (TC) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG