AUTOMATIC TRANSAXLE FLUID REPLACEMENT

PROCEDURE


  1. REPLACE AUTOMATIC TRANSAXLE FLUID


    1. Lift the vehicle. [*1]

      Note

      Set the vehicle on a lift so that the vehicle is kept level when it is lifted up (make sure that the tilt angle from the front to rear of the vehicle is within +/- 1°).

    2. Remove the No. 1 engine under cover.

      Click here

    3. Remove the rear engine under cover LH.

      Click here

    4. A01QU4H

      Remove the refill plug and gasket from the automatic transaxle. [*2]

    5. A01QOXJ

      Using a 6 mm hexagon socket wrench, remove the overflow plug and gasket from the automatic transaxle. [*3]

    6. A01QOLNC01
      *1 No. 1 Transmission Oil Filler Tube
      *2 Hexagon Socket Wrench
      *a Overflow Plug Hole

      Using a 6 mm hexagon socket wrench, remove the No. 1 transmission oil filler tube from the oil pan and drain the automatic transaxle fluid. [*4]

    7. A01QOHD

      Measure the amount of fluid that you drained. [*5]

      Tech Tips

      Add the same amount of fluid in step [*8].

    8. Using a 6 mm hexagon socket wrench, install the No. 1 transmission oil filler tube to the oil pan. [*6]

      Torque:
      1.7 N*m  { 17 kgf*cm, 15 in.*lbf }
    9. A01QOXJ

      Temporarily install the gasket and the overflow plug. [*7]

      Tech Tips

      Reuse the old gasket. The plug will be removed again to adjust the fluid level.

    10. A01QOBH

      Add fluid to the refill hole using the same amount of fluid drained in step [*5]. [*8]

      Note

      Use Toyota Genuine ATF WS.

    11. A01QU4H

      Temporarily install the gasket and refill plug to avoid fluid spillage. [*9]

      Tech Tips

      Reuse the old gasket. The plug will be removed again to adjust the fluid level.

    12. Lower the vehicle. [*10]

    13. Start the engine. [*11]

    14. Slowly move the shift lever from P to D, and then back to P. [*12]

    15. Allow the engine to idle for 30 seconds to warm it up. [*13]

    16. Turn the ignition switch off. [*14]

    17. Repeat steps [*1] to [*14].

    18. Repeat steps [*1] to [*10].

  2. ADJUST FLUID TEMPERATURE

    Click here

  3. ADJUST FLUID LEVEL

    Click here

  4. REBUILD WORK

    Click here