AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

Refer to DTC P2714.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) An open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • TCM

Comes on DTC stored

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.

WIRING DIAGRAM

A01QQAOE04
*a Shift Solenoid Valve SLT
*b Transmission Valve Body Assembly
*c Transmission Wire
*d Automatic Transaxle Assembly

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click here

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    1. A01QOXMC19
      *a

      Component without TCM connected

      (Transmission Wire)

      Remove the TCM.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      12 (SLT+) - 7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      12 (SLT+) - Body ground Always 10 kΩ or higher
      7 (SLT-) - Body ground Always 10 kΩ or higher
      12 (SLT+) - All other terminals except 7 (SLT-) Always 10 kΩ or higher
      7 (SLT-) - All other terminals except 12 (SLT+) Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01QTPTC16
      *1 Shift Solenoid Valve SLT

      Remove shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise
      Result
      Proceed to
      OK
      NG

    OK
    NG