09992-00095 | Automatic Transmission Oil |
|
09992-00231 | Adaptor C |
|
09992-00271 | Gauge Assy |
TCM
Tech Tips
The standard voltage at each TCM terminal is shown in the table below.
In the table, first follow the information under "Condition". Look under "Terminal No. (Symbol)" for the terminals to inspect. The standard voltage between the terminals is shown under "Specified Condition".
Use the illustration above as a reference for the TCM terminals.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| B79-15 (R) - B79-8 (E1) | R - BR | R position switch signal | Ignition switch ON and shift lever in R | 11 to 14 V |
| Ignition switch ON and shift lever in any position except R | Below 1 V | |||
| B79-16 (D) - B79-8 (E1) | B - BR | D position switch signal | Ignition switch ON and shift lever in D or M | 11 to 14 V |
| Ignition switch ON and shift lever in any position except D or M | Below 1 V | |||
| B79-12 (STP) - B79-8 (E1) | L - BR | Stop light switch signal | Brake pedal depressed | 7.5 to 14 V |
| Brake pedal released | Below 1.5 V | |||
| B79-11 (NSW) - B79-8 (E1) | W - BR | Park/neutral position switch signal | Ignition switch ON and shift lever in P or N | Below 2 V |
| Ignition switch ON and shift lever in any position except P or N | 11 to 14 V | |||
| B79-10 (STA) - B79-8 (E1) | LG - BR | Starter signal | Cranking (shift lever in P or N) | 6 V or higher |
| Ignition switch ON and shift lever in P or N | Below 2 V | |||
| B79-3 (SPD) - B79-8 (E1) | V - BR | Speed signal from combination meter | Vehicle driving | Pulse generation |
| B79-1 (BATT) - B79-8 (E1) | W - BR | Battery (for measuring battery voltage and for TCM memory) | Always | 11 to 14 V |
| B79-13 (IGSW) - B79-8 (E1) | Y - BR | Ignition switch | Ignition switch ON | 11 to 14 V |
| B79-18 (+B) - B79-8 (E1) | B - BR | Power source of TCM | Ignition switch ON | 11 to 14 V |
| B79-6 (CAN+) - B79-8 (E1) | Y - BR | CAN communication line | Ignition switch ON | Pulse generation |
| B79-7 (CAN-) - B79-8 (E1) | B - BR | CAN communication line | Ignition switch ON | Pulse generation |
ECM
Tech Tips
The standard voltage at each ECM terminal is shown in the table below.
In the table, first follow the information under "Condition". Look under "Terminal No. (Symbol)" for the terminals to inspect. The standard voltage between the terminals is shown under "Specified Condition".
Use the illustration below as a reference for the ECM terminals.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A61-9 (S) - B76-109 (E1) | L - BR | M position switch signal | Ignition switch ON and shift lever in M | 11 to 14 V |
| Ignition switch ON and shift lever not in M | Below 1 V | |||
| B76-61 (SFTU) - B76-109 (E1) | LG - BR | Up-shift position switch signal | Ignition switch ON and shift lever in M | 11 to 14 V |
|
Below 1 V | |||
| A61-28 (SFTD) - B76-109 (E1) | Y - BR | Down-shift position switch signal | Ignition switch ON and shift lever in M | 11 to 14 V |
|
Below 1 V | |||
| A61-36 (PWMS) - B76-109 (E1) | GR - BR | Combination switch (SPORT) signal | Ignition switch ON and combination switch (SPORT) off | 11 to 14 V |
| Ignition switch ON and combination switch (SPORT) on | Below 1.5 V |
*: w/ Shift Paddle Switch