AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P2810

DTC Code DTC Name
P2810 Pressure Control Solenoid "G" Electrical (Shift Solenoid Valve SL4)

DESCRIPTION

Changing from 1st to 6th is performed by the TCM turning shift solenoid valves SL1, SL2, SL3, SL4 and SL on and off. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2810 Pressure Control Solenoid "G" Electrical (Shift Solenoid Valve SL4) An open or short circuit (output signal duty is 0% or 100%) is detected by the TCM in the shift solenoid valve SL4 circuit while driving and shifting gears (SL4 output signal duty is more than 0% and less than 100% under normal conditions) (1-trip detection logic).
  • Open or short in shift solenoid valve SL4 circuit

  • Shift solenoid valve SL4

  • TCM

Comes on DTC stored

MONITOR DESCRIPTION

The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. The TCM also performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the TCM stops sending current to the circuit.)

Click here

WIRING DIAGRAM

A01QQAOE06
*a Shift Solenoid Valve SL4
*b Transmission Valve Body Assembly
*c Transmission Wire
*d Automatic Transaxle Assembly

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click here

Tech Tips

The following table shows normal operation of shift solenoid valve SL4 when the shift lever is in D:

TCM gear shift command 1st 2nd 3rd 4th 5th 6th
Shift solenoid valve SL4 OFF OFF ON OFF ON OFF

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL4)


    1. A01QOXMC21
      *a

      Component without TCM connected

      (Transmission Wire)

      Remove the TCM.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      22 (SL4+) - 21 (SL4-) 20°C (68°F) 5.0 to 5.6 Ω
      22 (SL4+) - Body ground Always 10 kΩ or higher
      21 (SL4-) - Body ground Always 10 kΩ or higher
      22 (SL4+) - All other terminals except 21 (SL4-) Always 10 kΩ or higher
      21 (SL4-) - All other terminals except 22 (SL4+) Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT SHIFT SOLENOID VALVE SL4


    1. A01QTPTC14
      *1 Shift Solenoid Valve SL4

      Remove shift solenoid valve SL4.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise
      Result
      Proceed to
      OK
      NG

    OK
    NG