STOP AND START SYSTEM(for 3ZR-FAE) Stop and Start System does not Operate (Battery Condition)

DESCRIPTION

When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.

Tech Tips

Data List items
Oper Permission (Battery) Oper Permission (Start Min Volt 1) Oper Permission (Start Min Volt 2) Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4) Oper Permission (Battery Current) Oper Permission (Integrated Current) Oper Prohibition (Jump Start)
Battery Type State of BBC Alternator Status Idling Stop Rate
Total Idling Stop Rate Battery Fluid Temperature Ambient Temp Sensor Status of Battery Charge Control
Battery Temp (Start) Min Voltage(Cranking) Min Volt(After Cranking) Battery Current
Integrated Current Hood Courtesy Switch Oper Prohibition (Manual Start) -

Note

If the Data List item Oper Permission (Battery) is "NG" even after correcting a certain problem using the diagnostic troubleshooting procedures, the problem may be due to the battery charge amount being temporarily low or the battery may be deteriorated. However, there may be multiple overlapping conditions which are causing system operation to be prohibited, so make sure to always confirm all the diagnostic troubleshooting procedures.

PROCEDURE


  1. CONFIRM MODEL


    1. Check whether a multi-information display is equipped.

      Result
      Result Proceed to
      Equipped A
      Not equipped B

    B
    A
  2. CHECK MULTI-INFORMATION DISPLAY


    1. Check whether the multi-information display displayed that the specified battery is not equipped.

      Tech Tips

      The multi-information display is displayed when the voltage decreases below the minimum voltage necessary for starting the non-specified battery when stop and start control is operated.

      Result
      Result Proceed to
      No display A
      Displayed in past B

    B
    A
  3. CHECK DTC OUTPUT


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Trouble Codes.

    5. Read the DTCs.


      Powertrain > Stop and Start > Trouble Codes
      Result
      Result Proceed to
      DTCs are not output A
      DTCs are output B

    B
    A
  4. READ VALUE USING GTS (OPER PERMISSION (BATTERY))

    Tech Tips

    Check whether stop and start control was prohibited based on the battery conditions or other conditions.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).

    2. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Type Range Diagnostic Note
      Oper Permission (Battery) Permission of stop and start control based on the battery conditions NG / OK OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed -

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Battery)
      Result
      Result Proceed to
      NG is displayed A
      OK is displayed B

    B
    A
  5. READ VALUE USING GTS (BATTERY TYPE)


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.

    5. Check the "Battery Type" Data List Item.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Battery Type Set battery type Specified / Other

      Specified: Specified battery

      Other: Non-specified battery

      -

      Powertrain > Stop and Start > Data List
      Tester Display
      Battery Type
    6. Check whether the battery is specified or not specified.

      Result
      Data List Battery Type Display Proceed to
      Specified A
      Other B

    B
    A
  6. READ VALUE USING GTS (OPER PROHIBITION (JUMP START))

    Tech Tips

    Check whether stop and start control was prohibited based on the jump start battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).

    2. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Prohibition (Jump Start) Prohibition of stop and start control based on the jump start condition Permit / Prohibit Prohibit: Engine started with the engine hood open and the ignition switch turned to ON When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Prohibition (Jump Start)
      Result
      Result Proceed to
      Permit is displayed (for CVT) A
      Permit is displayed (for Manual Transaxle) B
      Prohibit is displayed C

      Tech Tips


      • A jump start is determined if the engine is started with the engine hood open.

      • After turning the ignition switch off and waiting approximately 30 seconds, a jump start is determined to have not occurred if the engine is started with the engine hood closed.


    B
    C
    A
  7. READ VALUE USING GTS (STATE OF BBC)

    Tech Tips

    Check the operation of the backup boost converter.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC.

    2. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      State of BBC Backup boost converter status Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Reset status Normal: Backup boost converter operating normally
      • Cycle Err:


        • Abnormal output voltage cycle is detected

      • Overvol:


        • When the ignition switch is ON:


          1. Overvoltage is detected at the control IC power source within the backup boost converter

          2. Overheating is detected at the control IC power source within the backup boost converter


        • When boosting:


          1. Malfunction is detected in the feedback circuit in the backup boost converter

          2. Too high or low output voltage

      • Overload:


        • Overcurrent is detected.

      • Low Vol:


        • A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON.

      • Duty Err:


        • Abnormal duty ratio is detected


      Powertrain > Stop and Start > Data List
      Tester Display
      State of BBC
      Result
      Result Proceed to
      Normal is displayed A
      Normal is not displayed B

    B
    A
  8. READ VALUE USING GTS (ALTERNATOR STATUS)

    Tech Tips

    Check the power generation status of the generator.


    1. Start the engine and allow it to idle.

    2. Enter the following menus: Powertrain / Stop and Start / Data List / Alternator Status.

    3. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Alternator Status Generator power generation status Normal / Abnormal Normal: Generator operation normal -

      Powertrain > Stop and Start > Data List
      Tester Display
      Alternator Status
      Result
      Result Proceed to
      Normal is displayed A
      Abnormal is displayed B

    B
    A
  9. READ VALUE USING GTS (IDLING STOP RATE, TOTAL IDLING STOP RATE)

    Tech Tips

    Check the idling stop rate.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Idling Stop Rate and Total Idling Stop Rate.

    2. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Idling Stop Rate Rate of the idling stop time to the entire ignition switch ON time

      Min.: 0%

      Max.: 100%

      - -
      Total Idling Stop Rate Rate of total idling stop time

      Min.: 0%

      Max.: 100%

      - -

      Powertrain > Stop and Start > Data List
      Tester Display
      Idling Stop Rate
      Total Idling Stop Rate
      Result
      Result Proceed to
      Idling Stop Rate is 50% or lower and Total Idling Stop Rate is 40% or lower A
      Idling Stop Rate is higher than 50% or Total Idling Stop Rate is 40% or higher B

    B
    A
  10. READ VALUE USING GTS (BATTERY FLUID TEMPERATURE, AMBIENT TEMP SENSOR)

    Tech Tips

    Check the battery temperature.


    1. Enter the following menus: Powertrain / Stop and Start / Data List.

    2. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Battery Fluid Temperature Battery fluid temperature

      Min.: -40°C (-40°F)

      Max.: 100°C (212°F)

      Changes according to actual temperature: Driving after engine warmed up -
      Ambient Temp Sensor Ambient temperature

      Min.: -80°C (-112°F)

      Max.: 79.9°C (175.8°F)

      Close to ambient temperature -

      Powertrain > Stop and Start > Data List
      Tester Display
      Battery Fluid Temperature
      Ambient Temp Sensor
      Result
      Proceed to Proceed to

      Both Battery Fluid Temperature and Ambient Temp Sensor are suitable temperature

      (Battery Fluid Temperature: -10°C (14°F) to 70°C (158°F), Ambient Temp Sensor: -5°C (23°F) or higher)

      A

      Battery Fluid Temperature or Ambient Temp Sensor is not suitable temperature

      (Battery Fluid Temperature: -15°C (5°F) or less or 75°C (167°F) or higher, Ambient Temp Sensor: -6°C (21.2°F) or less)

      B

      Tech Tips

      The Battery Fluid Temperature hysteresis is 5°C (41°F) and the Ambient Temp Sensor hysteresis is 1°C (33.8°F).


    B
    A
  11. READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)

    Tech Tips

    Check whether stop and start control was prohibited based on the battery charge control mode.


    1. Start the engine and allow it to idle.

    2. Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.

    3. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Status of Battery Charge Control Battery charge control status Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode - -

      Powertrain > Stop and Start > Data List
      Tester Display
      Status of Battery Charge Control
      Result
      Result Proceed to
      "Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed A
      "Refresh Charge Mode" is displayed B
      "Abnormal Mode" is displayed C
      "Battery Condition Judgment Mode" is displayed D

    B
    C
    D
    A
  12. READ VALUE USING GTS (OPER PERMISSION (START MIN VOLT 1, 2, 3, 4))

    Tech Tips

    Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List.

    2. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Start Min Volt 1) Permission of stop and start control based on minimum voltage during starting when battery fluid temperature is 0°C (32°F) or less NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 2) Permission of stop and start control based on minimum voltage during starting when battery fluid temperature is more than 0°C (32°F) NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 3) Permission of stop and start control based on minimum voltage after cranking when battery fluid temperature is 0°C (32°F) or less NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 4) Permission of stop and start control based on minimum voltage after cranking when battery fluid temperature is more than 0°C (32°F) NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Start Min Volt 1)
      Oper Permission (Start Min Volt 2)
      Oper Permission (Start Min Volt 3)
      Oper Permission (Start Min Volt 4)
      Result
      Result Proceed to
      OK is displayed for 2 or more items A
      OK is displayed for 1 item or none B

      1. The Data List item "Oper Permission (Start Min Volt 1, 2, 3, 4)" is judged OK or NG according to the values of the following Data List items.


        Powertrain > Stop and Start > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Battery Temp (Start) Battery temperature at engine start

        Min.: -40°C (-40°F)

        Max.: 100°C (212°F)

        Same as temperature around battery at engine start (after engine start) -
        Min Voltage(Cranking) Minimum voltage when cranking engine

        Min.: 0 V

        Max.: 327.67 V

        6 to 11 V Lowest battery voltage measured in a 5 second period after the starter starts operating.
        Min Volt(After Cranking) Minimum voltage when starter begins operation

        Min.: 0 V

        Max.: 327.67 V

        6 to 11 V Minimum battery voltage while starter driving
        Battery Type Set battery type Specified / Other

        Specified: Specified battery

        Other: Non-specified battery

        -

        Powertrain > Stop and Start > Data List
        Tester Display
        Battery Temp (Start)
        Min Voltage(Cranking)
        Min Volt(After Cranking)
        Battery Type
        Permission Criteria (Specified Battery) for CVT
        Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
        Oper Permission (Start Min Volt 1) 8.14 V or higher - 0°C (32°F) or less
        Oper Permission (Start Min Volt 2) 8.14 V or higher - Higher than 0°C (32°F)
        Oper Permission (Start Min Volt 3) - 7.6 V or higher 0°C (32°F) or less
        Oper Permission (Start Min Volt 4) - 7.6 V or higher Higher than 0°C (32°F)
        Permission Criteria (Specified Battery) for Manual Transaxle:
        Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
        Oper Permission (Start Min Volt 1) 6.5 V or higher - 0°C (32°F) or less
        Oper Permission (Start Min Volt 2) 6.5 V or higher - Higher than 0°C (32°F)
        Oper Permission (Start Min Volt 3) - 6.5 V or higher 0°C (32°F) or less
        Oper Permission (Start Min Volt 4) - 6.5 V or higher Higher than 0°C (32°F)
        Permission Criteria (Non-specified Battery)
        Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
        Oper Permission (Start Min Volt 1) 8.92 V or higher - 0°C (32°F) or less
        Oper Permission (Start Min Volt 2) 8.92 V or higher - Higher than 0°C (32°F)
        Oper Permission (Start Min Volt 3) - 8.92 V or higher 0°C (32°F) or less
        Oper Permission (Start Min Volt 4) - 8.92 V or higher Higher than 0°C (32°F)

    B
    A
  13. READ VALUE USING GTS (OPER PERMISSION (INTEGRATED CURRENT))

    Tech Tips

    Check whether stop and start control was prohibited based on the integrated current value battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Integrated Current).

    2. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Integrated Current) Permission of stop and start control based on the integrated current value condition NG / OK OK: Integrated current value more than specified The status depends on the value of "Integrated Current", and the OK/NG threshold differs according to the battery temperature.

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Integrated Current)
      Result
      Result Proceed to
      OK is displayed A
      NG is displayed B

    B
    A
  14. READ VALUE USING GTS (OPER PERMISSION (BATTERY CURRENT))

    Tech Tips

    Check whether stop and start control was prohibited based on the battery discharge current battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery Current).

    2. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Battery Current) Permission of stop and start control based on battery current NG / OK OK: Battery discharge current is -125 A or higher Engine stop and start ECU calculated value

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Battery Current)
      Result
      Result Proceed to
      OK is displayed A
      NG is displayed B

      Tech Tips

      The Data List item "Oper Permission (Battery Current)" is judged OK or NG according to the values of the following Data List items.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Battery Current Battery current

      Min.: -125 A

      Max.: 124.99 A

      - -

      Powertrain > Stop and Start > Data List
      Tester Display
      Battery Current
      Permission Criteria
      Tester Display Battery Current
      Oper Permission (Battery Current) -125 A or higher

    A
    B
  15. CHECK BATTERY SETTINGS AND EQUIPPED BATTERY


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.

    5. Check the "Battery Type" Data List Item.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Battery Type Set battery type Specified / Other

      Specified: Specified battery

      Other: Non-specified battery

      -

      Powertrain > Stop and Start > Data List
      Tester Display
      Battery Type
    6. Check whether the battery is specified or not specified.

      Result
      Data List Battery Type Display Equipped Battery Proceed to
      Other Specified battery A
      Other Non-specified battery B

    B
    A
  16. SWITCH BATTERY TYPE


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Engine and ECT / Utility / Switch Battery Type.


      Powertrain > Engine and ECT > Utility
      Tester Display
      Switch Battery Type
    5. Perform Switch Battery Type under Utility and set the Specified battery.

    6. Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.

    7. Check that the "Battery Type" Data List item is set to "Specified".


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Battery Type Set battery type Specified / Other

      Specified: Specified battery

      Other: Non-specified battery

      -

      Powertrain > Stop and Start > Data List
      Tester Display
      Battery Type
      Result
      Proceed to
      NEXT

    NEXT
  17. READ VALUE USING GTS (OPER PROHIBITION (MANUAL START))

    Tech Tips

    Check whether the stop and start control was prohibited based on the manual start battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Manual Start).

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Prohibition (Manual Start) Prohibition of stop and start control based on the manual start conditions Permit / Prohibit Prohibit: During manual start

      When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.


        Conditions for Manual Start:

      • Clutch start switch OFF or vehicle speed signal input

      • Neutral position sensor (neutral position switch) OFF

      • Starter signal OFF


      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Prohibition (Manual Start)
      Result
      Result Proceed to
      Permit is displayed A
      Prohibit is displayed B

    A
    B
  18. READ VALUE USING GTS (INTEGRATED CURRENT)

    Tech Tips

    Judge the battery condition based on the integrated current value.


    1. Start the engine and allow it to idle.

    2. Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.

    3. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Integrated Current Battery integrated current

      Min.: -268434.45 A-sec

      Max.: 268435.45 A-sec

      Differs according to the vehicle condition (charge/discharge conditions) -

      Powertrain > Stop and Start > Data List
      Tester Display
      Integrated Current

      1. Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.


        Powertrain > Stop and Start > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Battery Fluid Temperature Battery fluid temperature

        Min.: -40°C (-40°F)

        Max.: 100°C (212°F)

        Changes according to actual temperature: Driving after engine warmed up -
        Battery Current Battery current

        Min.: -125 A

        Max.: 124.99 A

        - -
        Integrated Current Battery integrated current

        Min.: -268434.45 A-sec

        Max.: 268435.45 A-sec

        Differs according to the vehicle condition (charge/discharge conditions) -

        Powertrain > Stop and Start > Data List
        Tester Display
        Battery Fluid Temperature
        Battery Current
        Integrated Current
        Standard Integrated Current Value
        Status of Battery Charge Control Battery Fluid Temperature Integrated Current Proceed to
        Charge Control Coordination Mode or Stop and Start Standalone Mode -15°C (5°F) or higher or below 75°C (167°F) Below -13478 A-sec A
        Low Temperature Mode Between 3°C (37.4°F) and under 11°C (51.8°F) Below -6048 A-sec
        Low Temperature Mode Between -1°C (30.2°F) and under 3°C (37.4°F) Below -3974 A-sec
        Stop and Start Restriction Mode or Temperature High/Low Mode -15°C (5°F) or higher or below 75°C (167°F) Below 0 A-sec
        Stop and Start Restriction Mode or Temperature High/Low Mode Below -15°C (5°F) or 75°C (167°F) or higher - B
        Cause and Action to be Taken
        Result Cause Action to be Taken
        A Integrated current value is limited for the stop and start control due to discharge or deterioration of the battery Check the battery condition and recharge or replace the battery
        B Integrated current value is limited for stop and start control due to battery temperature (too high/low) Leave the battery under room temperature conditions until its temperature becomes as specified. Then check the battery condition and recharge or replace the battery.

        • Initialize* the battery integrated current using the GTS after charging the battery, and drive the vehicle until the stop and start control operates (approximately 5 to 40 minutes).

          *: Use the GTS to perform Integrated Current Value Initialization.

          Click here

          Tech Tips

          If the Data List item "Integrated Current" is 0 or higher, it is not necessary to perform initialization.

        • When the battery state sensor assembly current value is normal, recharge or replace the battery

        • When the electrical load is large, a large amount of electrical discharge occurs. As a result, the integrated current value (battery charge amount) tends to drop causing operation to be prohibited.

      Result
      Proceed to
      NEXT

    NEXT
  19. CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE


    1. Check the battery.

      Click here

      Tech Tips


      • Charge or replace the battery according to the check result.

      • When the cable is disconnected from the battery terminal or the charging control system is checked (ECM connector is disconnected), do not perform this procedure, as there is a high possibility that the system may enter refresh charge mode and operation may be prohibited.

    2. for CVT:

      Check the starter inrush current reduction relay.

      Click here

    3. Start the engine.

    4. Enter the following menus: Powertrain / Stop and Start / Data List.

    5. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Battery Current Battery current

      Min.: -125 A

      Max.: 124.99 A

      - -

      Powertrain > Stop and Start > Data List
      Tester Display
      Battery Current
    6. While idling, illuminate the headlights (Lo).

      Tech Tips

      The headlights (Lo) are illuminated so that charging control is prohibited, which sets the voltage to a fixed value.

    7. Charge the battery until the Data List item Battery Current becomes 5 A or less for approximately 5 minutes.

      Tech Tips

      The Data List item Battery Current decreases when the battery is charged. If the battery is charged for 5 minutes after Battery Current drops to 5 A or less, it can be determined that the battery issufficiently charged.

    8. Turn off the headlights.

    9. Turn the ignition switch off and wait for 30 seconds or more.

    10. Start the engine and check the following Data List items.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Min Voltage(Cranking) Minimum voltage when cranking engine

      Min.: 0 V

      Max.: 327.67 V

      6 to 11 V Lowest battery voltage measured after the starter starts operating.
      Min Volt(After Cranking) Minimum voltage when starter begins operation

      Min.: 0 V

      Max.: 327.67 V

      6 to 11 V Minimum battery voltage while starter operating
      Oper Permission (Start Min Volt 1) Permission of stop and start control based on minimum voltage during starting when battery fluid temperature is 0°C (32°F) or less NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 2) Permission of stop and start control based on minimum voltage during starting when battery fluid temperature is more than 0°C (32°F) NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 3) Permission of stop and start control based on minimum voltage after cranking when battery fluid temperature is 0°C (32°F) or less NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 4) Permission of stop and start control based on minimum voltage after cranking when battery fluid temperature is more than 0°C (32°F) NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Powertrain > Stop and Start > Data List
      Tester Display
      Min Voltage(Cranking)
      Min Volt(After Cranking)
      Oper Permission (Start Min Volt 1)
      Oper Permission (Start Min Volt 2)
      Oper Permission (Start Min Volt 3)
      Oper Permission (Start Min Volt 4)
      Permission Criteria (Specified Battery) for CVT
      Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
      Oper Permission (Start Min Volt 1) 8.14 V or higher - 0°C (32°F) or less
      Oper Permission (Start Min Volt 2) 8.14 V or higher - Higher than 0°C (32°F)
      Oper Permission (Start Min Volt 3) - 7.6 V or higher 0°C (32°F) or less
      Oper Permission (Start Min Volt 4) - 7.6 V or higher Higher than 0°C (32°F)
      Permission Criteria (Specified Battery) for Manual Transaxle:
      Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
      Oper Permission (Start Min Volt 1) 6.5 V or higher - 0°C (32°F) or less
      Oper Permission (Start Min Volt 2) 6.5 V or higher - Higher than 0°C (32°F)
      Oper Permission (Start Min Volt 3) - 6.5 V or higher 0°C (32°F) or less
      Oper Permission (Start Min Volt 4) - 6.5 V or higher Higher than 0°C (32°F)
      Permission Criteria (Non-specified Battery)
      Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
      Oper Permission (Start Min Volt 1) 8.92 V or higher - 0°C (32°F) or less
      Oper Permission (Start Min Volt 2) 8.92 V or higher - Higher than 0°C (32°F)
      Oper Permission (Start Min Volt 3) - 8.92 V or higher 0°C (32°F) or less
      Oper Permission (Start Min Volt 4) - 8.92 V or higher Higher than 0°C (32°F)
    11. Replace the battery in the following situations.


      • Oper Permission (Start Min Volt (1, 2, 3, 4)) are not OK

      • Oper Permission (Start Min Volt (1, 2, 3, 4)) are OK, but Min Voltage (Cranking) and Min Volt (After Cranking) values are close to permission criteria

      Result
      Proceed to
      NEXT

    NEXT
  20. READ VALUE USING GTS (HOOD COURTESY SWITCH)

    Tech Tips

    Check the engine hood courtesy switch (hood lock assembly).


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.

    2. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Hood Courtesy Switch Hood courtesy switch signal ON / OFF

      ON: Engine hood closed

      OFF: Engine hood opened

      -

      Powertrain > Stop and Start > Data List
      Tester Display
      Hood Courtesy Switch
      Result
      Result Proceed to
      When engine hood condition changes from open to closed, Data List switches from OFF to ON A
      When engine hood condition changes from open to closed, Data List remains OFF B

      Tech Tips

      If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.


    B
    A
  21. READ VALUE USING GTS (OPER PROHIBITION (JUMP START))


    1. Check that the engine hood is closed.

    2. Turn the ignition switch off and wait for 30 seconds or more.

    3. Turn the ignition switch to ON.

    4. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).

    5. Check that the Data List item "Oper Prohibition (Jump Start)" displays "Permit".


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Prohibition (Jump Start) Prohibition of stop and start control based on the jump start condition Permit / Prohibit Prohibit: Engine started with the engine hood open and the ignition switch turned to ON When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Prohibition (Jump Start)
      Result
      Proceed to
      NEXT

      Tech Tips

      Stop and start control may be prohibited if the engine was started with the engine hood open.


    NEXT