STOP AND START SYSTEM(for 3ZR-FAE) Stop and Start Cancel Switch Circuit

DESCRIPTION

Stop and start control can be disabled by pressing the stop and start system cancel switch (combination switch assembly). The stop and start system cancel switch (combination switch assembly) is a momentary-type switch that switches between on and off when the switch is pressed. While stop and start control is disabled, the stop and start cancel indicator light is illuminated to inform the driver.

WIRING DIAGRAM

A01QSI1E47
*a Stop and Start System Cancel Switch (Combination Switch Assembly)
*b Engine Stop and Start ECU

PROCEDURE


  1. READ VALUE USING GTS (CANCEL SWITCH)


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Data List / Cancel Switch.

    5. Read the value when the stop and start system cancel switch (ecorun cancel switch assembly) is pressed.


      Powertrain > Stop and Start > Data List
      Tester Display
      Cancel Switch
      OK
      Tester Display Condition Normal Condition
      Cancel Switch Stop and start system cancel switch (ecorun cancel switch assembly) is pressed ON
      Stop and start system cancel switch (ecorun cancel switch assembly) is not pressed OFF
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT STOP AND START SYSTEM CANCEL SWITCH (COMBINATION SWITCH ASSEMBLY)


    1. Inspect the stop and star system cancel switch (combination switch assembly).

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (STOP AND START SYSTEM CANCEL SWITCH (COMBINATION SWITCH ASSEMBLY) - BODY GROUND)


    1. Disconnect the G185 stop and start system cancel switch (combination switch assembly) connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G185-6 (MSW2) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - STOP AND START SYSTEM CANCEL SWITCH (COMBINATION SWITCH ASSEMBLY))


    1. Disconnect the G87 engine stop and start ECU connector.

    2. Disconnect the G185 stop and start system cancel switch (combination switch assembly) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G87-5 (ECAN) - G185-5 (ECU) Always Below 1 Ω
      G87-5 (ECAN) - Body ground Always 10 kΩ or higher
      G185-5 (ECU) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG