STOP AND START SYSTEM(for 3ZR-FAE) Stop and Start Cancel Switch Circuit

DESCRIPTION

Stop and start control can be disabled by pressing the stop and start system cancel switch (ecorun cancel switch assembly). The stop and start system cancel switch (ecorun cancel switch assembly) is a momentary-type switch that switches between on and off when the switch is pressed. While stop and start control is disabled, the stop and start cancel indicator light is illuminated to inform the driver.

WIRING DIAGRAM

A01KAU4E33

PROCEDURE


  1. READ VALUE USING GTS (CANCEL SWITCH)


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Data List / Cancel Switch.

    5. Read the value when the stop and start system cancel switch (ecorun cancel switch assembly) is pressed.

      OK
      Tester Display Condition Normal Condition
      Cancel Switch Stop and start system cancel switch (ecorun cancel switch assembly) is pressed ON
      Stop and start system cancel switch (ecorun cancel switch assembly) is not pressed OFF
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT STOP AND START SYSTEM CANCEL SWITCH (ECORUN CANCEL SWITCH ASSEMBLY)


    1. Inspect the stop and star system cancel switch (ecorun cancel switch assembly).

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (STOP AND START SYSTEM CANCEL SWITCH (ECORUN CANCEL SWITCH ASSEMBLY) - BODY GROUND)


    1. Disconnect the G162 stop and start system cancel switch (ecorun cancel switch assembly) connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G162-5 (E) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - STOP AND START SYSTEM CANCEL SWITCH (ECORUN CANCEL SWITCH ASSEMBLY))


    1. Disconnect the G87 engine stop and start ECU connector.

    2. Disconnect the G162 stop and start system cancel switch (ecorun cancel switch assembly) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G87-23 (ECAN) - G162-8 (ECU) Always Below 1 Ω
      G87-23 (ECAN) - Body ground Always 10 kΩ or higher
      G162-8 (ECU) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG