DIFFERENTIAL PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL DIFFERENTIAL PRESSURE SENSOR ASSEMBLY


    1. A00YTKYC01
      *1 Paint Mark (Yellow)
      *2 Paint Mark (Red)
      *a Front Side of Vehicle
      *b LH Side

      Connect the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly to the differential pressure sensor assembly, and slide the 2 clamps to secure the hoses.

      Note

      Connect the vacuum transmitting hoses so that the painted marks of the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly are as shown in the illustration.

    2. Install the differential pressure sensor assembly with the nut.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    3. Connect the differential pressure sensor connector.