2WW BATTERY / CHARGING SERVICE DATA

Battery Standard Specific Gravity 1.25 or higher at 20°C (68°F)
Standard Voltage 12.3 V or higher at 20°C (68°F)
Fuse Standard Resistance Below 1 Ω
Charging circuit without load Standard Current 10 A or higher
Standard Voltage 12.1 to 15.4 V
Charging circuit with load Standard Current 30 A or higher
HARNESS AND CONNECTOR.

B126-1 (LIN) or A58-6 (LIN1) - Body ground

Tester Connection Condition Specified Condition
B126-1 (LIN) - A58-6 (LIN1) Always Below 1 Ω
B126-1 (LIN) or A58-6 (LIN1) - Body ground

Ignition switch off

(while LIN communication is stopped)

10 kΩ or higher
GENERATOR ASSEMBLY
Generator brush holder assembly Brush length Standard exposed length 11.2 mm (0.441 in.)
Minimum exposed length 2.0 mm (0.0787 in.)