3ZR-FAE STARTING SERVICE DATA

STARTER ASSEMBLY
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal SL2 11.5 V Below 130 A
STARTER ARMATURE ASSEMBLY
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Starter armature core 10 kΩ or higher
Commutator for runout Maximum Runout 0.05 mm (0.00197 in.)
Commutator diameter Standard Diameter 29 mm (1.1417 in.)
Minimum Diameter 28 mm (1.1024 in.)
Undercut depth Standard Undercut Depth 0.7 mm (convex part) (0.0276 in.)
Minimum Undercut Depth 0.4 mm (convex part) (0.0157 in.)
STARTER BRUSH HOLDER ASSEMBLY
Brush length Standard Length 14.4 mm (0.567 in.)
Minimum Length 9 mm (convex part) (0.354 in.)
Tester Connection Condition Specified Condition

A - B

A - C

B - D

C - D

Always 10 kΩ or higher

A - D

B - C

Below 1 Ω
Brush spring load Standard Spring Load 22 to 27 N (2 to 3 kgf, 4.9 to 6.1 lbf)
Minimum Spring Load 14 N (1 kgf, 3.1 lbf)
REPAIR SERVICE STARTER KIT
Tester Connection Condition Specified Condition
Terminal SL1 - Magnet switch body Always Below 1 Ω
Terminal SL2 - Magnet switch body Below 2 Ω
ENGINE SWITCH
Tester Connection Switch Condition Specified Condition
5 (SS1) - 6 (AGND) Not pushed 10 kΩ or higher
1 (SS2) - 6 (AGND)
5 (SS1) - 6 (AGND) Pushed Below 1 Ω
1 (SS2) - 6 (AGND)
Condition Specified Condition

Battery positive (+) → Terminal 9 (SWIL)

Battery negative (-) → Terminal 6 (AGND)

Illuminates
IGNITION SWITCH
Tester Connection Switch Condition Specified Condition
All combinations of all terminals LOCK 10 kΩ or higher
5 (AM1) - 7 (ACC) ACC Below 1 Ω
5 (AM1) - 7 (ACC) ON Below 1 Ω
5 (AM1) - 8 (IG1)
4 (AM2) - 3 (IG2)
6 (ST1) - 5 (AM1) STRAT Below 1 Ω
6 (ST1) - 8 (IG1)
2 (ST2) - 4 (AM2)
2 (ST2) - 3 (IG2)
STARTER RELAY (ST) (w/o Stop and Start System)
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
STARTER NO. 1 RELAY (ST NO. 1) (w/ Stop and Start System)
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
STARTER NO. 2 RELAY (ST NO. 2) (w/ Stop and Start System)
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω