1AD-FTV STARTING SERVICE DATA

GLOW PLUG
Tester Connection Condition Specified Condition
Glow plug terminal - Body ground 20°C (68°F) 0.28 Ω or higher
STARTER ASSEMBLY (w/ Stop And Start System)
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal 50 11.5 V Below 190 A
STARTER ASSEMBLY (w/o Stop And Start System)
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal 50 11.5 V 150 A or less
STARTER ARMATURE ASSEMBLY (Standard Resistance)
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Coil core Always 10 kΩ or higher
STARTER ARMATURE ASSEMBLY (w/ Stop And Start System)
Standard Diameter 35.0 mm (1.37 in.)
Minimum Diameter 34.0 mm (1.34 in.)
Maximum runout 0.05 mm (0.00197 in.)
Standard undercut depth 0.7 mm (0.0276 in.)
Minimum undercut depth 0.2 mm (0.00787 in.)
STARTER ARMATURE ASSEMBLY (w/o Stop And Start System)
Standard Diameter 29.0 mm (1.14 in.)
Minimum Diameter 28.0 mm (1.10 in.)
Maximum runout 0.05 mm (0.00197 in.)
Standard undercut depth 0.4 mm (0.0157 in.)
Minimum undercut depth 0.2 mm (0.00787 in.)
STARTER YOKE ASSEMBLY (w/ Stop And Start System)
Tester Connection Condition Specified Condition
Lead wire - Brush Always Below 1 Ω
Brush - Starter yoke body Always 10 kΩ or higher
BRUSH (w/ Stop And Start System)
Standard Length 15.0 mm (0.591 in.)
Minimum Length 9.0 mm (0.354 in.)
BRUSH (w/o Stop And Start System)
Standard Length 14.4 mm (0.567 in.)
Minimum Length 9.0 mm (0.354 in.)
STARTER BRUSH HOLDER ASSEMBLY (w/ Stop And Start System)
Standard Resistance 10 kΩ or higher
Brush Spring Standard Spring Installed Load 21.5 to 27.5 N (2 to 3 kgf, 4.8 to 6.2 lbf)
Minimum Spring Installed Load 12.3 N (1 kgf, 2.8 lbf)
STARTER BRUSH HOLDER ASSEMBLY (w/o Stop And Start System)
Brush Spring Standard Spring Installed Load 22.3 to 27.3 N (2 to 3 kgf, 5.0 to 6.1 lbf)
Minimum Spring Installed Load 13.8 N (1 kgf, 3.1 lbf)
STARTER MAGNETIC SWITCH ASSEMBLY
Tester Connection Condition Specified Condition
Terminal 50 - Terminal C Always Below 1 Ω
Terminal 50 - Switch body Always Below 2 Ω
STARTER RELAY (ST)
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applided to terminals 1 and 2 Below 1 Ω
GLOW PLUG RELAY
Tester Connection Condition Specified Condition
1 - 2 Battery voltage not applied to terminals 3 and 4 10 kΩ or higher
Battery voltage applided to terminals 3 and 4 Below 1 Ω