2WW COOLING SERVICE DATA

Coolant
Item Capacity Classification
w/o Combustion Type Power Heater 7.0 liters (7.4 US qts, 6.2 Imp. qts) Toyota recommends the use of approved "Toyota Premium Long Life Coolant for 2WW engines" or equivalent.
w/ Combustion Type Power Heater 7.3 liters (7.7 US qts, 6.4 Imp. qts)
Thermostat
Condition Specified Condition
Standard valve opening temperature 100 °C (212 °F)
Cooling Fan Motor
Item Condition Specified Condition
Cooling fan motor Battery voltage applied at 20°C (68°F) 12.2 to 15.7 A
No. 2 cooling fan motor Battery voltage applied at 20°C (68°F) 12.2 to 15.7 A
Radiator
Item Condition Specified Condition
Reservoir Cap

Standard pressure

(for brand-new reservoir cap)

126 to 143 kPa (1.3 to 1.5 kgf/cm2, 18 to 21 psi)

Minimum standard value

(for used cap)

101 kPa (1.0 kgf/cm2, 15 psi)