| Item | Capacity | Classification |
|---|---|---|
| w/o Combustion Type Power Heater | 7.0 liters (7.4 US qts, 6.2 Imp. qts) | Toyota recommends the use of approved "Toyota Premium Long Life Coolant for 2WW engines" or equivalent. |
| w/ Combustion Type Power Heater | 7.3 liters (7.7 US qts, 6.4 Imp. qts) |
| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 100 °C (212 °F) |
| Item | Condition | Specified Condition |
|---|---|---|
| Cooling fan motor | Battery voltage applied at 20°C (68°F) | 12.2 to 15.7 A |
| No. 2 cooling fan motor | Battery voltage applied at 20°C (68°F) | 12.2 to 15.7 A |
| Item | Condition | Specified Condition |
|---|---|---|
| Reservoir Cap | Standard pressure (for brand-new reservoir cap) |
126 to 143 kPa (1.3 to 1.5 kgf/cm2, 18 to 21 psi) |
| Minimum standard value (for used cap) |
101 kPa (1.0 kgf/cm2, 15 psi) |