ПЕРЕПУСКНОЙ РАСПРЕДЕЛИТЕЛЬНЫЙ КЛАПАН РОГ ПРОВЕРКА

PROCEDURE


  1. INSPECT EGR BYPASS VALVE SWITCHING VALVE (NO. 1 VACUUM SWITCHING VALVE ASSEMBLY)


    1. A00YBD4C01
      *a Component without harness connected (EGR Bypass Valve Switching Valve (No. 1 Vacuum Switching Valve Assembly))

      Inspect the EGR bypass valve switching valve (No. 1 vacuum switching valve assembly) resistance.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 20°C (68°F) 33 to 39 Ω

        If the result is not as specified, replace the EGR bypass valve switching valve (No. 1 vacuum switching valve assembly).

    2. A00Y8X6C01
      *a Port E
      *b Port F
      *c Filter
      *d Air

      Apply battery voltage between the terminals of the EGR bypass valve switching valve (No. 1 vacuum switching valve assembly) and check that the following occurs when blowing air to the port (E).

      OK
      Measurement Condition Specified Condition
      Battery voltage applied between terminals 1 and 2 Air flows from port (F)
      Battery voltage not applied between terminals 1 and 2 Air flows from filter

      If the result is not as specified, replace the EGR bypass valve switching valve (No. 1 vacuum switching valve assembly).