КЛАПАН РЕГУЛИРОВАНИЯ ВСАСЫВАНИЯ СНЯТИЕ

CAUTION / NOTICE / HINT

Tech Tips

After replacing the suction control valve, perform the "SUPPLY PUMP INITIALIZATION PROCEDURE" function using the GTS.

Click here

PROCEDURE


  1. REMOVE NO. 1 ENGINE COVER

    Click here

  2. REMOVE AIR CLEANER CAP SUB-ASSEMBLY

    Click here

  3. REMOVE AIR CLEANER CASE SUB-ASSEMBLY

    Click here

  4. CLEAN SUCTION CONTROL VALVE AND SURROUNDING AREA


    1. Using cleaning spray or a brush, clean the suction control valve assembly and the area around it.

      Note

      After cleaning with cleaning spray, do not blow air. Doing so may cause any dust or sand to fly and adhere to the cleaned area.

  5. REMOVE SUCTION CONTROL VALVE ASSEMBLY

    Note


    • Before replacing the suction control valve assembly, be sure to clean the area around it.

    • When replacing the suction control valve assembly, make sure that your hands are clean. Do not use gloves, etc.


    1. A00Y5UZ

      Disconnect the connector from the suction control valve assembly.

    2. Using a 5 mm hexagon wrench, remove the 2 bolts, suction control valve assembly and O-ring from the fuel supply pump assembly.

      Note


      • Do not reuse the suction control valve assembly or O-ring.

      • Make sure that the O-ring does not remain attached to the fuel supply pump assembly.