ДАТЧИК МАССОВОГО РАСХОДА ВОЗДУХА УСТАНОВКА

PROCEDURE


  1. INSTALL MASS AIR FLOW METER SUB-ASSEMBLY

    Tech Tips

    Perform "Air Flow Meter Learning Value Reset" after replacing the mass air flow meter sub-assembly.

    Click here


    1. Using a T20 "TORX" socket wrench, install the mass air flow meter sub-assembly to the air cleaner cap sub-assembly with the 2 screws.

      Torque:
      1.5 N*m  { 15 kgf*cm, 13 in.*lbf }

      Note

      If the mass air flow meter sub-assembly has been struck or dropped, replace it.

    2. Connect the mass air flow meter sub-assembly connector.

  2. PERFORM INITIALIZATION


    1. Perform "Air Flow Meter Learning Value Reset" after replacing the mass air flow meter sub-assembly.

      Click here