НАГНЕТАЮЩИЙ ТОПЛИВНЫЙ НАСОС (для моделей без контроллера свечей накаливания) ПРОВЕРКА

PROCEDURE


  1. INSPECT SUPPLY PUMP ASSEMBLY

    A012GTRC01
    *a

    Component without harness connected

    (Suction Control Valve)

    *b

    Component without harness connected

    (Fuel Temperature Sensor)


    1. Inspect the resistance of the suction control valve.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Terminals Condition Resistance
        1 - 2 20°C (68°F) 2.60 to 3.15 Ω

        If the result is not as specified, replace the supply pump assembly.

    2. Inspect the resistance of the fuel temperature sensor.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Terminals Condition Resistance
        1 - 2 -20°C (-4°F) 13.92 to 17.01 kΩ
        1 - 2 0°C (32°F) 5.31 to 6.49 kΩ
        1 - 2 20 °C (68°F) 2.25 to 2.75 kΩ
        1 - 2 40°C (104°F) 1.06 to 1.29 kΩ
        1 - 2 60°C (140°F) 0.54 to 0.66 kΩ
        1 - 2 80 °C (176°F) 0.29 to 0.36 kΩ
        1 - 2 100°C (212°F) 0.17 to 0.20 kΩ

        If the result is not as specified, replace the supply pump assembly.