PROCEDURE
INSPECT DIESEL TURBO PRESSURE SENSOR
Inspect the power source voltage.
Disconnect the connector from the diesel turbo pressure sensor.
Turn the ignition switch to ON.
| *a | Front view of wire harness connector (to Diesel Turbo Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the ignition switch off.
Reconnect the diesel turbo pressure sensor connector.
Inspect the diesel turbo pressure sensor.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Map and Atmosphere Pressure.
| Tester Display |
|---|
| Atmosphere Pressure |
| MAP |
Disconnect the vacuum hose from the diesel turbo pressure sensor.
Using SST, apply pressure to the diesel turbo pressure sensor.
Using a vacuum pump, apply vacuum to the diesel turbo pressure sensor.
Read the value.
| OK | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the diesel turbo pressure sensor connector.