AIR CONDITIONING SYSTEM ECO Switch Circuit

DESCRIPTION

When the combination switch assembly (ECO switch) is turned on, the air conditioning amplifier assembly receives an combination switch assembly (ECO switch) ON signal and controls the air conditioning to enhance fuel efficiency.

WIRING DIAGRAM

A01SFNGE05

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the values by referring to the table below.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      ECO Switch Combination switch assembly (ECO switch) OFF or ON

      Combination switch assembly (ECO switch) not operated: OFF /

      Combination switch assembly (ECO switch) operated: ON

      -

      Body Electrical > Air Conditioner > Data List
      Tester Display
      ECO Switch
      OK
      Combination switch assembly (ECO switch) condition displayed on the GTS changes with the actual switch operation.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT COMBINATION SWITCH ASSEMBLY (ECO SWITCH)


    1. Remove the combination switch assembly (ECO switch).

      Click here

    2. Measure the resistance according to the value(s) in the table below.

      A01SFI4C01
      *a

      Component without harness connected

      (Combination Switch Assembly (ECO Switch))

      - -
      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (ECU) - 3 (E) Combination switch assembly (ECO switch) off (when switch is not pressed) 10 kΩ or higher
      2 (ECU) - 3 (E) Combination switch assembly (ECO switch) on (when switch is pressed) Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (COMBINATION SWITCH (ECO SWITCH) - AIR CONDITIONING AMPLIFIER ASSEMBLY)


    1. Disconnect the E28 air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E28-24 (ECOS) - E114-2 (ECU) Always Below 1 Ω
      E28-24 (ECOS) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (COMBINATION SWITCH (ECO SWITCH) - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E114-3 (E) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK