PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE SERVICE PLUG GRIP
CHECK TERMINAL VOLTAGE
Remove the inverter cover.
Check the terminal voltage.
Install the inverter cover.
REMOVE INLET AIR CLEANER ASSEMBLY
DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the discharge hose sub-assembly from the compressor with motor assembly.
Remove the O-ring from the discharge hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the suction hose sub-assembly from the compressor with motor assembly.
Remove the O-ring from the suction hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
REMOVE COMPRESSOR WITH MOTOR ASSEMBLY
| *a | Green-colored Lock |
|
Slide |
Using a screwdriver, slide the green-colored lock of the connector <A> as shown in the illustration to release it and disconnect the connector.
CAUTION:
Make sure to wear insulating gloves.
Note
Insulate the removed terminals and connector with insulating tape.
Disconnect the connector <B>.
Remove the 3 bolts and compressor with motor assembly.