COMPRESSOR REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

    Click here

  2. REMOVE SERVICE PLUG GRIP

    Click here

  3. CHECK TERMINAL VOLTAGE


    1. Remove the inverter cover.

      Click here

    2. Check the terminal voltage.

      Click here

    3. Install the inverter cover.

      Click here

  4. REMOVE INLET AIR CLEANER ASSEMBLY

    Click here

  5. DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY


    1. A01KSEV

      Remove the bolt and disconnect the discharge hose sub-assembly from the compressor with motor assembly.

    2. Remove the O-ring from the discharge hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  6. DISCONNECT SUCTION HOSE SUB-ASSEMBLY


    1. A01KR4W

      Remove the bolt and disconnect the suction hose sub-assembly from the compressor with motor assembly.

    2. Remove the O-ring from the suction hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  7. REMOVE COMPRESSOR WITH MOTOR ASSEMBLY


    1. A01KTGJC01
      *a Green-colored Lock
      A01KSJJ Slide

      Using a screwdriver, slide the green-colored lock of the connector <A> as shown in the illustration to release it and disconnect the connector.

      CAUTION:

      Make sure to wear insulating gloves.

      Note

      Insulate the removed terminals and connector with insulating tape.

    2. Disconnect the connector <B>.

    3. A01KTRK

      Remove the 3 bolts and compressor with motor assembly.