PROCEDURE
INSTALL COOLER EXPANSION VALVE
Apply sufficient compressor oil to 2 new O-rings and the fitting surfaces of the cooler expansion valve.
| Compressor Oil |
|---|
| ND-OIL 11 or equivalent |
Install the 2 O-rings to the No. 1 cooler evaporator sub-assembly.
Using a 4 mm hexagon wrench, install the cooler expansion valve with the 2 hexagon bolts.
CONNECT AIR CONDITIONER TUBE ASSEMBLY
CONNECT SUCTION PIPE SUB-ASSEMBLY
Remove the vinyl tape from the suction pipe sub-assembly.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the suction pipe sub-assembly.
| Compressor Oil |
|---|
| ND-OIL 11 or equivalent |
Install the O-ring to the suction pipe sub-assembly.
Connect the suction pipe sub-assembly.
Rotate the hook connector as shown in the illustration.
Insert the pipe joint into the fitting hole securely and install the bolt.
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
WARM UP COMPRESSOR
INSPECT FOR REFRIGERANT LEAK