COOLER EXPANSION VALVE INSTALLATION

PROCEDURE


  1. INSTALL COOLER EXPANSION VALVE


    1. Apply sufficient compressor oil to 2 new O-rings and the fitting surfaces of the cooler expansion valve.

      Compressor Oil
      ND-OIL 11 or equivalent
    2. Install the 2 O-rings to the No. 1 cooler evaporator sub-assembly.

    3. Using a 4 mm hexagon wrench, install the cooler expansion valve with the 2 hexagon bolts.

      Torque:
      3.5 N*m  { 36 kgf*cm, 31 in.*lbf }
  2. CONNECT AIR CONDITIONER TUBE ASSEMBLY

    Click here

  3. CONNECT SUCTION PIPE SUB-ASSEMBLY


    1. Remove the vinyl tape from the suction pipe sub-assembly.

    2. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the suction pipe sub-assembly.

      Compressor Oil
      ND-OIL 11 or equivalent
    3. Install the O-ring to the suction pipe sub-assembly.

    4. Connect the suction pipe sub-assembly.

    5. A01KT1T

      Rotate the hook connector as shown in the illustration.

    6. Insert the pipe joint into the fitting hole securely and install the bolt.

      Torque:
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
  4. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT

    Click here

  5. WARM UP COMPRESSOR

    Click here

  6. INSPECT FOR REFRIGERANT LEAK

    Click here