COOLER EXPANSION VALVE REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

    Click here

  2. DISCONNECT SUCTION PIPE SUB-ASSEMBLY

    Click here

  3. DISCONNECT AIR CONDITIONER TUBE ASSEMBLY

    Click here

  4. REMOVE COOLER EXPANSION VALVE


    1. A01KS0D

      Using a 4 mm hexagon wrench, remove the 2 hexagon bolts.

    2. A01KT2MC01
      *a Bolt for Suction Pipe Sub-assembly

      Temporarily install the bolt for the suction pipe sub-assembly halfway to the cooler expansion valve.

    3. A01KSNB

      Hold the bolt and pull it to remove the cooler expansion valve as shown in the illustration.

    4. A01KTC5C01
      *1 No. 1 Cooler Evaporator Sub-assembly

      Remove the 2 O-rings from the No. 1 cooler evaporator sub-assembly.