PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFC-134a(R134a))
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFO-1234yf(R1234yf))
REMOVE SERVICE PLUG GRIP
CHECK TERMINAL VOLTAGE
Remove the inverter cover.
Check the terminal voltage.
Install the inverter cover.
REMOVE INLET AIR CLEANER ASSEMBLY
DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the discharge hose sub-assembly from the compressor with motor assembly.
Remove the O-ring from the discharge hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the suction hose sub-assembly from the compressor with motor assembly.
Remove the O-ring from the suction hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
REMOVE COMPRESSOR WITH MOTOR ASSEMBLY
| *a | Green-colored Lock |
|
Slide |
Using a screwdriver, slide the green-colored lock of the connector <A> as shown in the illustration to release it and disconnect the connector.
CAUTION:
Make sure to wear insulating gloves.
Note
Insulate the removed terminals and connector with insulating tape.
Disconnect the connector <B>.
Remove the 3 bolts and compressor with motor assembly.