| DTC No. | Detection Item | DTC Detection Condition | Link |
|---|---|---|---|
| B1411/11 | Room Temperature Sensor Circuit | Open or short in cooler (room temp. sensor) thermistor circuit | |
| B1412/12 | Ambient Temperature Sensor Circuit | Open or short in ambient temperature sensor circuit | |
| B1413/13 | Evaporator Temperature Sensor Circuit | Open or short in evaporator temperature sensor circuit | |
| B1423/23 | Pressure Sensor Circuit |
|
|
| B1441/41 | Air Mix Damper Control Servo Motor Circuit (Passenger Side) | Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates air mix damper servo sub-assembly (for front passenger side) (for dual type) or air mix damper servo sub-assembly (for single type) | |
| B1442/42 | Air Inlet Damper Control Servo Motor Circuit | Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates recirculation damper servo sub-assembly | |
| B1443/43 | Air Outlet Damper Control Servo Motor Circuit | Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates mode damper servo sub-assembly | |
| B1446/46 | Air Mix Damper Control Servo Motor Circuit (Driver Side) | Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates air mix damper servo sub-assembly (for driver side) | |
| B1471/71 | A/C Inverter High Voltage Power Resource System Malfunction |
|
|
| B1472/72 | A/C Inverter High Voltage Output System Malfunction | Open or short in A/C inverter high voltage output system | |
| B1473/73 | A/C Inverter Start-up Signal System Malfunction | Open or short in A/C inverter start-up signal system | |
| B1474/74 | A/C Inverter Malfunction | A/C inverter malfunction | |
| B1475/75 | A/C Inverter Cooling / Heating System Malfunction | Temperature of the inverter is outside the specified range (temperature is too high), or there is an open or short to ground in the temperature sensor circuit | |
| B1476/76 | A/C Inverter Load System Malfunction | Motor rotation load while the compressor is operating is too large or too small | |
| B1477/77 | A/C Inverter Low Voltage Power Resource System Malfunction | An open or short to ground in the inverter control power voltage circuit | |
| B1497/97 | BUS IC Communication Malfunction | Error or open in communication line | |
| B1498/98 | Communication Malfunction (A/C Inverter Local) |
|
|
| B14A2 | Driver Side Solar Sensor Short Circuit | Short in driver side cooler (solar sensor) thermistor (for dual type) or cooler (solar sensor) thermistor (for single type) circuit | |
| B14A3 | Front Passenger Side Solar Sensor Short Circuit | Short in front passenger side cooler (solar sensor) thermistor circuit | |
| B14B2 | Lost Communication with Front Panel LIN | Lost communication with air conditioning control assembly | |
| B14B8 | Refrigerant Shortage | When the following condition is detected in refrigerant shortage check in normal operation: Amount of refrigerant is insufficient |
|
| P0AA6-611 | Hybrid Battery Voltage System Isolation Fault | High voltage system insulation malfunction | |
| U0131 | Lost Communication with Electric Power Steering ECU | No communication with electric power steering ECU | |
| U0142 | Lost Communication with Main Body ECU | No communication with main body ECU | |
| U0155 | Lost Communication with Combination Meter | No communication with combination meter | |
| U0293 | Lost Communication with HV ECU | No communication with HV ECU |