AIR CONDITIONING SYSTEM DATA LIST / ACTIVE TEST


  1. DATA LIST

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

    Tech Tips

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Read the Data List according to the display on the GTS.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temperature Sensor Cooler (room temp. sensor) thermistor

      Min.: -6.50°C (20.30°F)

      Max.: 57.25°C (135.05°F)

      Actual cabin temperature displayed -
      Ambient Temp Sensor Thermistor assembly

      Min.: -23.30°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed -
      Adjusted Ambient Temp Adjusted ambient temperature

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      - -
      Evaporator Fin Thermistor No. 1 cooler thermistor

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed -
      Evaporator Target Temp Evaporator target temperature

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Evaporator target temperature displayed -
      Solar Sensor (D Side) Driver side cooler (solar sensor) thermistor*1 or cooler (solar sensor) thermistor*2

      Min.: 0

      Max.: 255

      Driver side cooler (solar sensor) thermistor*1 or cooler (solar sensor) thermistor*2 value increases as brightness increases -
      Solar Sensor (P Side) Front passenger side cooler (solar sensor) thermistor

      Min.: 0

      Max.: 255

      Front passenger side cooler (solar sensor) thermistor value increases as brightness increases *1
      Engine Coolant Temp Engine coolant temperature sensor

      Min.: 1.30°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed -
      Set Temperature (D Side) Driver side set temperature*1 or set temperature*2

      Min.: MAX COLD

      Max.: MAX HOT

      Driver side set temperature*1 or set temperature*2 displayed -
      Set Temperature (P Side) Front passenger side set temperature

      Min.: MAX COLD

      Max.: MAX HOT

      Front passenger side set temperature displayed *1
      Blower Motor Speed Level Blower motor speed level

      Min.: 0

      Max.: 31

      Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
      Regulator Pressure Sensor Air conditioner pressure sensor

      Min.: -456.6 kPaG

      Max.: 3294.3 kPaG

      Actual refrigerant pressure displayed -
      Air Mix Servo Targ Pulse(D) Air mix damper servo sub-assembly (for driver side)*1 or air mix damper servo sub-assembly*2 target pulse

      Min.: 0

      Max.: 255


        for LHD:

      • MAX COLD: 92 (pulse)

      • MAX HOT: 5 (pulse)


        for RHD:

      • MAX COLD: 6 (pulse)

      • MAX HOT: 93 (pulse)

      -
      Air Mix Servo Actual Pulse(D) Air mix damper servo sub-assembly (for driver side)*1 or air mix damper servo sub-assembly*2 actual pulse

      Min.: 0

      Max.: 255


        for LHD:

      • MAX COLD: 92 (pulse)

      • MAX HOT: 5 (pulse)


        for RHD:

      • MAX COLD: 6 (pulse)

      • MAX HOT: 93 (pulse)

      -
      Air Mix Servo Targ Pulse(P) Air mix damper servo sub-assembly (for front passenger side) target pulse

      Min.: 0

      Max.: 255


        for LHD:

      • MAX COLD: 6 (pulse)

      • MAX HOT: 93 (pulse)


        for RHD:

      • MAX COLD: 92 (pulse)

      • MAX HOT: 5 (pulse)

      *1
      Air Mix Servo Actual Pulse(P) Air mix damper servo sub-assembly (for front passenger side) actual pulse

      Min.: 0

      Max.: 255


        for LHD:

      • MAX COLD: 6 (pulse)

      • MAX HOT: 93 (pulse)


        for RHD:

      • MAX COLD: 92 (pulse)

      • MAX HOT: 5 (pulse)

      *1
      Air Outlet Servo Pulse (D) Mode damper servo sub-assembly target pulse

      Min.: 0

      Max.: 255

      FACE: 47 (pulse)

      B/L: 37 (pulse)

      FOOT: 18 (pulse)

      FOOT/DEF: 9 (pulse)

      DEF: 5 (pulse)

      -
      Air Outlet Servo Actu Pulse(D) Mode damper servo sub-assembly actual pulse

      Min.: 0

      Max.: 255

      FACE: 47 (pulse)

      B/L: 37 (pulse)

      FOOT: 18 (pulse)

      FOOT/DEF: 9 (pulse)

      DEF: 5 (pulse)

      -
      Air Inlet Damper Targ Pulse Recirculation damper servo sub-assembly target pulse

      Min.: 0

      Max.: 255


        for LHD:

      • RECIRCULATION: 19 (pulse)

      • FRESH: 7 (pulse)


        for RHD:

      • RECIRCULATION: 7 (pulse)

      • FRESH: 25 (pulse)

      -
      Air Inlet Damper Actual Pulse Recirculation damper servo sub-assembly actual pulse

      Min.: 0

      Max.: 255


        for LHD:

      • RECIRCULATION: 19 (pulse)

      • FRESH: 7 (pulse)


        for RHD:

      • RECIRCULATION: 7 (pulse)

      • FRESH: 25 (pulse)

      -
      Electric Heater Count Maximum electric heater operation level

      Min.: 0

      Max.: 3

      Maximum possible operation of electric heater displayed *3
      Electric Heater Active Level Actual electric heater operation level

      Min.: 0

      Max.: 3

      Actual operation level of electric heater displayed *3
      Compressor Speed Compressor speed

      Min.: 0 rpm

      Max.: 65535 rpm

      Actual compressor rotation speed displayed -
      Compressor Target Speed Compressor target rotation speed displayed

      Min.: 0 rpm

      Max.: 65535 rpm

      Compressor target rotation speed displayed -
      Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
      Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
      Noise and Vibration Reduction Noise and vibration reduction OFF or ON Customized value displayed -
      ECO MODE Cancel ECO mode cancel OFF or ON Customized value displayed -
      ECO Switch Combination switch assembly (ECO switch) OFF or ON

      Combination switch assembly (ECO switch) not operated: OFF /

      Combination switch assembly (ECO switch) operated: ON

      -
      Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
      Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
      Foot/DEF Auto Mode Foot/defroster auto mode ON or OFF Customized value displayed -
      Foot/DEF Auto Blow Up Foot/defroster auto blower speed increase ON or OFF Customized value displayed -
      Compressor Drive Check Compressor drive check OK or NG

      NG: Compressor does not drive

      OK: Compressor drives

      -
      Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
      Outside Air Mode Auto Switch Function Outside air mode auto switch function ON or OFF Customized value displayed -
      Number of Trouble Codes Number of trouble codes

      Min.: 0

      Max.: 255

      Number of DTCs displayed -

      • *1: for Dual Type

      • *2: for Single Type

      • *3: w/ PTC Heater

  2. ACTIVE TEST

    Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Perform the Active Test according to the display on the GTS.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -
      Compressor Target Speed Compressor with motor assembly Min.: 0, Max.: 7500 -
      Defogger Relay (Rear) Defogger relay OFF, ON -
      Heater Active Level Quick heater assembly Min.: 0, Max.: 3 *3
      Air Mix Servo Targ Pulse(D) Air mix damper servo sub-assembly (for driver side)*1 or air mix damper servo sub-assembly*2 pulse Min.: 0, Max.: 255

        for LHD

      • Operates between 5 and 92 pulses


        for RHD

      • Operates between 6 and 93 pulses

      Air Mix Servo Targ Pulse(P) Air mix damper servo sub-assembly (for front passenger side) pulse Min.: 0, Max.: 255

        for LHD

      • Operates between 6 and 93 pulses


        for RHD

      • Operates between 5 and 92 pulses

      *1

      Air Outlet Servo Pulse (D) Mode damper servo sub-assembly pulse Min.: 0, Max.: 255 Operates between 5 and 47 pulses
      Air Inlet Damper Targ Pulse Recirculation damper servo sub-assembly pulse Min.: 0, Max.: 255

        for LHD

      • Operates between 7 and 19 pulses


        for RHD

      • Operates between 7 and 25 pulses


      • *1: for Dual Type

      • *2: for Single Type

      • *3: w/ PTC Heater