RELAY INSPECTION

PROCEDURE


  1. INSPECT TSS C HTR RELAY


    1. A0031ZW

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω
      1 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
      2 - 3 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher

      If the result is not as specified, replace the TSS C HTR relay.