LIGHTING SYSTEM IG Signal Circuit

DESCRIPTION

This circuit detects the power switch on (IG) or off condition, and sends it to the main body ECU (multiplex network body ECU).

WIRING DIAGRAM


  1. A00YNTCE07

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. Read the Data List according to the display on the GTS.


      Body Electrical > Main Body > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      IG SW Power switch on (IG) signal ON or OFF

      ON: Power switch on (IG)

      OFF: Power switch off

      -

      Body Electrical > Main Body > Data List
      Tester Display
      IG SW
      OK
      Normal conditions listed above are displayed.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (IG1 NO. 3 RELAY POWER SOURCE)


    1. A00YOJ6C05
      *a

      Component with harness connected

      (Instrument Panel Junction Block Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      3D-24 - Body ground Power switch on (IG) 11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - AUXILIARY BATTERY AND BODY GROUND)


    1. Disconnect the 3B and 3C instrument panel junction block assembly connectors.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      3B-1 - Body ground Power switch off 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3C-9 - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3C-17 - 3C-51 Always Below 1 Ω
      3C-17 - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  5. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (IG1 NO. 3 RELAY)


    1. Remove the instrument panel junction block assembly.

      for RHD: Click here

      for LHD: Click here

    2. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

    3. Measure the resistance according to the value(s) in the table below.

      A00YNJLC02
      *a

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      - -
      Standard Resistance
      Tester Connection Condition Specified Condition
      3C-51 - MB-32 (IG) Always Below 1 Ω
      3B-1 - 3C-17 Auxiliary battery not connected to 3D-24 and 3C-9 10 kΩ or higher
      3B-1 - 3C-17

      Auxiliary battery positive (+) → 3D-24

      Auxiliary battery negative (-) → 3C-9

      Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG