PROCEDURE
INSPECT SECURITY INDICATOR LIGHT (CLOCK ASSEMBLY)
Component without harness connected
(Security Indicator Light (Clock Assembly))
Apply battery voltage to the connector according to the table below.
Battery positive (+) → Terminal 9
Battery negative (-) → Terminal 8