PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
Note
When disconnecting the cable from the negative (-) auxiliary battery terminal, initialize the following system after the cable is reconnected.
| System Name | See Procedure |
|---|---|
| Simple Intelligent Parking Assist System | |
| Power Door Lock Control System |
PRECAUTIONS WHEN USING GTS
When using the GTS with the vehicle power switch off, connect the GTS to the vehicle and turn a courtesy light switch on and off at intervals of 1.5 seconds or less until communication between the GTS and the vehicle begins. Then select the Model Code "KEY REGIST" under manual mode and enter the following menus: Body Electrical / Entry&Start(CAN). While using the GTS, periodically turn a courtesy light switch on and off at intervals of 1.5 seconds or less to maintain communication between the GTS and the vehicle.
After all DTCs are cleared, check if the malfunction occurs again 6 seconds after the power switch is turned on (IG).