ГЕНЕРАТОР УСТАНОВКА

PROCEDURE


  1. INSTALL GENERATOR ASSEMBLY


    1. Install the wire harness clamp bracket to the generator assembly with the bolt.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    2. Using an E8 "TORX" socket wrench, temporarily install the generator assembly with the stud bolt.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    3. Install the generator assembly with the bolt and 2 nuts.

      Torque:
      25 N*m  { 255 kgf*cm, 18 ft.*lbf }
    4. Engage the wire harness clamp.

    5. Connect the generator assembly connector.

    6. Connect the wire harness to terminal B with the nut.

      Torque:
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
    7. Install the terminal cap.

  2. INSTALL V-RIBBED BELT

    Click here

  3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here