PROCEDURE
PRECAUTION
Note
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
REMOVE V-RIBBED BELT
REMOVE GENERATOR ASSEMBLY
Remove the terminal cap.
Remove the nut and disconnect the wire harness from terminal B.
Disconnect the generator assembly connector.
Disengage the wire harness clamp.
Remove the bolt and 2 nuts.
Using an E8 "TORX" socket wrench, remove the stud bolt.
Remove the generator assembly.
Remove the bolt and wire harness clamp bracket from the generator assembly.