PROCEDURE
CONFIRM PROBLEM SYMPTOM
Confirm the problem symptom.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO STEP 6 Click here |
| A |
|
CHECK V-RIBBED BELT FOR WEAR
Check the V-ribbed belt for wear or damage.
| OK |
|---|
| The V-ribbed belt is not worn or damaged. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE V-RIBBED BELT Click here |
| OK |
|
CHECK GENERATOR WITH CLUTCH PULLEY FOR WEAR
Check the generator with clutch pulley grooves for wear or damage.
| OK |
|---|
| The generator with clutch pulley grooves are not worn or damaged. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE GENERATOR WITH CLUTCH PULLEY Click here |
| OK |
|
CHECK FOR NOISE WHILE CLUTCH PULLEY IS OPERATING
Start the engine and check the generator with clutch pulley for looseness.
| OK |
|---|
| The generator with clutch pulley with clutch is not loose. |
| Result | |||
|---|---|---|---|
|
| NG |
|
TIGHTEN GENERATOR WITH CLUTCH PULLEY TO SPECIFIED TORQUE |
| OK |
|
INSPECT GENERATOR WITH CLUTCH PULLEY (UNIT INSPECTION)
Remove the generator assembly.
Check the installation condition of the generator pulley cap.
| OK |
|---|
| The generator pulley cap is not loose or missing. |
Check for forming of particles due to friction (for dry type pulley) or grease leaks (for wet type pulley).
| OK |
|---|
| There are no large amount of particles (for dry type pulley) or grease leaks (for wet type pulley). |
Check the generator with clutch pulley for misalignment (interference with the generator assembly).
| OK |
|---|
| The generator with clutch pulley is not misaligned (no interference with the generator assembly). |
Turn the generator with clutch pulley clockwise and counterclockwise by hand and check for noise.
| OK |
|---|
| Noise does not occur when turned in both directions. |
Turn the generator with clutch pulley clockwise and counterclockwise by hand and visually check for runout.
| OK |
|---|
| The generator with clutch pulley does not have runout. |
Hold the generator rotor assembly (fan) in the generator assembly with a screwdriver, and check that the generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise.
| OK |
|---|
| The generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise. |
| Result | |||
|---|---|---|---|
|
| OK |
|
INSPECT PULLEY OTHER THAN GENERATOR ASSEMBLY PULLEY Click here |
| NG |
|
REPLACE GENERATOR WITH CLUTCH PULLEY Click here |
CHECK FOR NOISE WHEN ROTOR IS TURNING FREELY
Perform a road test and check that noise does not occur when decelerating.
| OK |
|---|
| Noise does not occur. |
Stop the engine and check that generator with clutch pulley noise does not occur as the engine stops.
| OK |
|---|
| Noise does not occur. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE GENERATOR PULLEY WITH CLUTCH Click here |
| OK |
|
CHECK ENGAGEMENT OF GENERATOR WITH CLUTCH PULLEY
Remove the generator assembly.
Hold the generator rotor assembly (fan) in the generator assembly with a screwdriver, and check that the generator with clutch pulley locks when turned from counterclockwise (free turning direction) to clockwise (locking direction).
| OK |
|---|
| The generator with clutch pulley locks. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPAIR OR REPLACE GENERATOR ASSEMBLY Click here |
| NG |
|
REPLACE GENERATOR WITH CLUTCH PULLEY Click here |