LIGHTING SYSTEM Hazard Warning Switch Circuit

DESCRIPTION

The combination meter assembly receives the hazard warning signal switch assembly ON signal and controls the operation of the hazard warning lights.

WIRING DIAGRAM

A013AKFE02

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Combination Meter / Data List.

    5. Read the display on the GTS.


      Body Electrical > Combination Meter > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Hazard Flasher Switch Hazard warning signal switch signal ON or OFF

      ON: Hazard warning signal switch on

      OFF: Hazard warning signal switch off

      -

      Body Electrical > Combination Meter > Data List
      Tester Display
      Hazard Flasher Switch
      OK
      Normal conditions listed above are displayed.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    1. Remove the hazard warning signal switch assembly.

      Click here

    2. A0139TYC02
      *a

      Component without harness connected

      (Hazard Warning Signal Switch Assembly)

      for LHD:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4 (TB) - 1 (E) Hazard warning signal switch on Below 1 Ω
        Hazard warning signal switch off 10 kΩ or higher
    3. A013ARUC05
      *a

      Component without harness connected

      (Hazard Warning Signal Switch Assembly)

      for RHD:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4 (TB) - 1 (E) Hazard warning signal switch on Below 1 Ω
        Hazard warning signal switch off 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND)


    1. Disconnect the E45 combination meter assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      E96-4 (TB) - E45-3 (HAZ) Always Below 1 Ω
      E96-4 (TB) - Body ground Always 10 kΩ or higher
      E96-1 (E) - Body ground Always Below 1 Ω
      for RHD
      Tester Connection Condition Specified Condition
      E121-4 (TB) - E45-3 (HAZ) Always Below 1 Ω
      E121-4 (TB) - Body ground Always 10 kΩ or higher
      E121-1 (E) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG