POWER WINDOW REGULATOR MOTOR(for Front Door) INSPECTION

PROCEDURE


  1. INSPECT FRONT DOOR WINDOW REGULATOR ASSEMBLY LH (w/ Jam Protection Function)

    CAUTION:

    Prevent any part of your body from being caught during inspection.


    1. A00YO6PC01
      *a

      Component without harness connected

      (Front Door Window Regulator Assembly LH)

      *b Up
      *c Down

      Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).

      Note

      Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a negative (-) auxiliary battery to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that window regulator moves smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 10 (UP) within 1 second.

      Arm of window regulator rotates clockwise (Up)

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 7 (DOWN) within 1 second.

      Arm of window regulator rotates counterclockwise (Down)

      • If the result is not as specified, replace the front door window regulator assembly LH.

      Note

      Initialize the power window control system after installing the front door window regulator assembly LH.

  2. INSPECT FRONT DOOR WINDOW REGULATOR ASSEMBLY LH (w/o Jam Protection Function)

    CAUTION:

    Prevent any part of your body from being caught during inspection.


    1. A00YNW2C01
      *a

      Component without harness connected

      (Front Door Window Regulator Assembly LH)

      *b Up
      *c Down

      Apply auxiliary battery voltage to the motor connector according to the table below.

      Note

      Do not apply auxiliary battery voltage to any terminals except terminals 1 and 2.

      Standard
      Measurement Condition Specified Condition

      Auxiliary battery positive (+) → Terminal 2

      Auxiliary battery negative (-) → Terminal 1

      Arm of window regulator rotates clockwise (Up)

      Auxiliary battery positive (+) → Terminal 1

      Auxiliary battery negative (-) → Terminal 2

      Arm of window regulator rotates counterclockwise (Down)

      If the result is not as specified, replace the front door window regulator assembly LH.

  3. INSPECT FRONT DOOR WINDOW REGULATOR ASSEMBLY RH (w/ Jam Protection Function)

    CAUTION:

    Prevent any part of your body from being caught during inspection.


    1. A00YN8EC01
      *a

      Component without harness connected

      (Front Door Window Regulator Assembly RH)

      *b Up
      *c Down

      Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).

      Note

      Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a negative (-) auxiliary battery to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that window regulator moves smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 10 (UP) within 1 second.

      Arm of window regulator rotates counterclockwise (Up)

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 7 (DOWN) within 1 second.

      Arm of window regulator rotates clockwise (Down)

      • If the result is not as specified, replace the front door window regulator assembly RH.

      Note

      Initialize the power window control system after installing the front door window regulator assembly RH.

  4. INSPECT FRONT DOOR WINDOW REGULATOR ASSEMBLY RH (w/o Jam Protection Function)

    CAUTION:

    Prevent any part of your body from being caught during inspection.


    1. A00YNNZC01
      *a

      Component without harness connected

      (Front Door Window Regulator Assembly RH)

      *b Up
      *c Down

      Apply auxiliary battery voltage to the motor connector according to the table below.

      Note

      Do not apply auxiliary battery voltage to any terminals except terminals 1 and 2.

      Standard
      Measurement Condition Specified Condition

      Auxiliary battery positive (+) → Terminal 1

      Auxiliary battery negative (-) → Terminal 2

      Arm of window regulator rotates clockwise (Down)

      Auxiliary battery positive (+) → Terminal 2

      Auxiliary battery negative (-) → Terminal 1

      Arm of window regulator rotates counterclockwise (Up)