POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on Driver Door Window Only) Power Windows do not Operate Using All Window Switch

DESCRIPTION

The power windows operate by using the power window regulator master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly (for LH door or RH door)*.

The power window regulator master switch assembly, power window regulator switch assembly and rear power window regulator switch assemblies (for LH door or RH door)* connect the same power supply and ground lines.

*: w/ Rear Power Window

WIRING DIAGRAM

A0139AKE03
A013AN3E01
A013AN3E02

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (POWER WINDOW MASTER SWITCH ASSEMBLY - AUXILIARY BATTERY AND BODY GROUND)


    1. Disconnect the H11*1 or G11*2 power window regulator master switch assembly connector.


      • *1: for LHD

      • *2: for RHD

    2. Measure the voltage and resistance according to the value(s) in the table below.

      Standard Voltage
      for LHD with Rear Power Window
      Tester Connection Condition Specified Condition
      H11-6 (B) - Body ground Power switch on (IG) 11 to 14 V
      for LHD without Rear Power Window
      Tester Connection Condition Specified Condition
      H11-15 (B) - Body ground Power switch on (IG) 11 to 14 V
      for RHD with Rear Power Window
      Tester Connection Condition Specified Condition
      G11-6 (B) - Body ground Power switch on (IG) 11 to 14 V
      for RHD without Rear Power Window
      Tester Connection Condition Specified Condition
      G11-15 (B) - Body ground Power switch on (IG) 11 to 14 V
      Standard Resistance
      for LHD with Rear Power Window
      Tester Connection Condition Specified Condition
      H11-1 (E) - Body ground Always Below 1 Ω
      for LHD without Rear Power Window
      Tester Connection Condition Specified Condition
      H11-7 (E) - Body ground Always Below 1 Ω
      for RHD with Rear Power Window
      Tester Connection Condition Specified Condition
      G11-9 (E) - Body ground Always Below 1 Ω
      for RHD without Rear Power Window
      Tester Connection Condition Specified Condition
      G11-7 (E) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY


    1. Replace the power window regulator master switch assembly.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  3. CHECK POWER WINDOW CONTROL SYSTEM


    1. Check the operation of the power windows by using the power window regulator master switch assembly, power window regulator switch assembly and rear power window regulator switch assemblies (for LH door or RH door)*.

      *: w/ Rear Power Window

      Click here

      OK
      All power windows operate normally.
      Result
      Proceed to
      OK
      NG

    OK
    NG