HYBRID BATTERY SYSTEM, Diagnostic DTC:U029A-123

DTC Code DTC Name
U029A-123 Lost Communication with Hybrid Battery Pack Sensor Module

DESCRIPTION

The battery voltage sensor detects the HV battery conditions (voltage, current, and temperature) and the battery cooling fan frequency, and sends the detected signals to the power management control ECU via serial communication. (The power management control ECU does not send signals to the battery voltage sensor.)

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
U029A-123 Lost Communication with Hybrid Battery Pack Sensor Module Serial communication error between the battery voltage sensor and the power management control ECU (The power management control ECU did not receive signals from the battery voltage sensor.) (1 trip detection)
  • Wire harness or connector

  • Power management control ECU

  • Battery voltage sensor

Comes on Comes on

WIRING DIAGRAM

A01KU4AE01

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here

    Tech Tips

    At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here

Tech Tips

After the repair, clear the DTCs, turn the power switch on (IG), wait for 1 minute or more and check for DTCs.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.

      Result
      Result Proceed to
      Only U029A-123 is output. A
      DTCs except U029A-123 are also output. B

      Powertrain > Hybrid Control > Trouble Codes
    5. Turn the power switch off.

    6. Disconnect the GTS from the DLC3.


    B
    A
  2. CHECK BATTERY VOLTAGE SENSOR (IGCT VOLTAGE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 2 hybrid battery intake duct.

      Click here

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01KRXYC07
      *a

      Component with harness connected

      (Battery Voltage Sensor)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L48-3 (IGCT) - L48-6 (GND) Power switch on (IG) 11 to 14 V

      Note

      Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

      Tech Tips

      As there might be an intermittent malfunction in the battery voltage sensor power source circuit, inspect the following even if the measured voltage is as specified:


      • Installation condition of fuse(s) (before removing fuse(s)) (IGCT circuit)

      • Fuse condition (before and after removing fuse(s)) (IGCT circuit)

      • Connection condition of connectors (IGCT circuit)

      • Wire harness condition (IGCT circuit)

      • Wire harness condition (GND circuit)

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Install the No. 2 hybrid battery intake duct.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BATTERY VOLTAGE SENSOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the E111 power management control ECU connector.

      Note

      Before disconnecting the connector, push in on the connector body to check that the connector is not loose or disconnected.

    3. Remove the No. 2 hybrid battery intake duct.

      Click here

    4. Disconnect the L48 battery voltage sensor connector.

      Note


      • Before disconnecting the connector, push in on the connector body to check that the connector is not loose or disconnected.

      • Push in on each connector between the power management control ECU and the battery voltage sensor to check that each connector is not loose or disconnected.

    5. Measure the resistance according to the value(s) in the table below.

      A01KRSRC05
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b

      Rear view of wire harness connector

      (to Battery Voltage Sensor)

      Standard Resistance
      Tester Connection Condition Specified Condition
      E111-32 (BTH+) - L48-1 (BTH+) Power switch off Below 1 Ω
      E111-33 (BTH-) - L48-4 (BTH-) Power switch off Below 1 Ω
      L48-1 (BTH+) - L48-6 (GND) and Body ground Power switch off 10 kΩ or higher
      L48-4 (BTH-) - L48-6 (GND) and Body ground Power switch off 10 kΩ or higher
    6. A01KRFBC01
      *1 Engine Room Relay Block and Junction Block Assembly
      *2 AM2 fuse
      *3 PM-IGCT fuse

      Remove the AM2 fuse and PM-IGCT fuse from the engine room relay block and junction block assembly.

    7. Disconnect the A129, A130 and E112 power management control ECU connectors.

    8. Measure the resistance according to the value(s) in the table below.

      A01KR1RC03
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      - -
      Standard Resistance
      Tester Connection Condition Specified Condition
      E111-32 (BTH+) - E112-7 (AM21) Power switch off 10 kΩ or higher
      E111-32 (BTH+) - E111-1 (AM22) Power switch off 10 kΩ or higher
      E111-32 (BTH+) - A129-2 (+B2) Power switch off 10 kΩ or higher
      E111-32 (BTH+) - A130-5 (+B1) Power switch off 10 kΩ or higher
      E111-32 (BTH+) - A130-6 (MREL) Power switch off 10 kΩ or higher
      E111-32 (BTH+) - A130-1 (IG2) Power switch off 10 kΩ or higher
      E111-32 (BTH+) - E112-1 (ACCD) Power switch off 10 kΩ or higher
      E111-32 (BTH+) E112-2 (IG1D) Power switch off 10 kΩ or higher
      E111-32 (BTH+) - A130-2 (IG2D) Power switch off 10 kΩ or higher
      E111-32 (BTH+) - E111-14 (SPDI) Power switch off 10 kΩ or higher
      E111-32 (BTH+) - A129-4 (FCTL) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - E112-7 (AM21) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - E111-1 (AM22) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - A129-2 (+B2) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - A130-5 (+B1) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - A130-6 (MREL) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - A130-1 (IG2) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - E112-1 (ACCD) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - E112-2 (IG1D) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - A130-2 (IG2D) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - E111-14 (SPDI) Power switch off 10 kΩ or higher
      E111-33 (BTH-) - A129-4 (FCTL) Power switch off 10 kΩ or higher

      Note

      When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.

    9. Install the AM2 fuse and PM-IGCT fuse to the engine room relay block and junction block assembly.

    10. Reconnect the L48 battery voltage sensor connector.

    11. Install the No. 2 hybrid battery intake duct.

    12. Reconnect the A129, A130, E111 and E112 power management control ECU connectors.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK POWER MANAGEMENT CONTROL ECU

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 2 hybrid battery intake duct.

      Click here

    3. Disconnect the L48 battery voltage sensor connector.

    4. Connect the cable to the negative (-) auxiliary battery terminal.

    5. Turn the power switch on (IG).

    6. A01KTWFC07
      *a

      Rear view of wire harness connector

      (to Battery Voltage Sensor)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L48-1 (BTH+) - L48-6 (GND) Power switch on (IG) 2.3 to 2.7 V
      L48-4 (BTH-) - L48-6 (GND) Power switch on (IG) 2.3 to 2.7 V

      Note

      Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    7. Turn the power switch off.

    8. Disconnect the cable from the negative (-) auxiliary battery terminal.

    9. A01KTWFC08
      *a

      Rear view of wire harness connector

      (to Battery Voltage Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L48-1 (BTH+) - L48-4 (BTH-) Power switch off 4.4 to 5.4 kΩ

      Tech Tips

      Resistance becomes 2.0 kΩ or less when there is a short circuit in the power management control ECU.

    10. Reconnect the L48 battery voltage sensor connector.

    11. Install the No. 2 hybrid battery intake duct.

      Result
      Proceed to
      OK
      NG

    OK
    NG