| DTC Code | DTC Name |
|---|---|
| P06B0-163 | Sensor Power Supply "A" Circuit / Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit / Open |
| P06E6-164 | Sensor Power Supply "C" Circuit / Open |
| P0A1A-151 | Generator Control Module |
| P0A1A-166 | Generator Control Module |
| P0A1A-658 | Generator Control Module |
| P0A1A-791 | Generator Control Module |
| P0A1B-198 | Drive Motor "A" Control Module |
| P0A1B-786 | Drive Motor "A" Control Module |
| P0A1B-794 | Drive Motor "A" Control Module |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C73-512 | Sensor Standard Voltage "F" Circuit / Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
DESCRIPTION
The MG ECU located in the inverter with converter assembly monitors its internal operation and it will store DTCs when it detects malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P06B0-163 | Sensor Power Supply "A" Circuit / Open | IPM positive power source error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P06D6-511 | Sensor Reference Voltage "F" Circuit / Open | Standard voltage for analog signal offset error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P06E6-164 | Sensor Power Supply "C" Circuit / Open | IPM negative power source error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-151 | Generator Control Module | Run pulse signal cycle deviation or stop | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-166 | Generator Control Module | R/D converter NM stop error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-658 | Generator Control Module | ALU error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-791 | Generator Control Module | R/D converter communication error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-198 | Drive Motor "A" Control Module | R/D converter NM stop error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-786 | Drive Motor "A" Control Module | ALU error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-794 | Drive Motor "A" Control Module | R/D converter communication error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P1C2A-155 | Generator A/D Converter Circuit | A/D converter error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit | A/D converter error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P1C73-512 | Sensor Standard Voltage "F" Circuit / Open | Standard voltage for analog signal error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P1CA6-156 | Generator Control Module Malfunction | CPU ROM-RAM error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P1CA7-193 | Drive Motor Control Module Malfunction | CPU ROM-RAM error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P3133-659 | Communication Error from Generator to Drive Motor "A" | Communication error (from MG1 to MG2) | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P3134-661 | Communication Error from Drive Motor "A" to Generator | Communication error (from MG2 to MG1) | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Check for DTCs.
| Result | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||
|
Turn the power switch off.
| B |
|
REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS Click here |
| A |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL) Click here |
| A |
|
CLEAR DTC
| Result | ||
|---|---|---|
|
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read and record the DTCs and freeze frame data.
Clear the DTCs and freeze frame data.
Turn the power switch off.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Turn the power switch off.
| A |
|
REPLACE MG CONTROL COMPUTER Click here |
| B |
|
REPLACE POWER MODULE INTELLIGENT TRANSISTOR KIT AND MG CONTROL COMPUTER Click here |
| C |
|
GO TO DTC CHART (HYBRID CONTROL) Click here |