| DTC Code | DTC Name |
|---|---|
| P0A1A-151 | Generator Control Module |
| P0A1A-155 | Generator Control Module |
| P0A1A-156 | Generator Control Module |
| P0A1A-166 | Generator Control Module |
| P0A1A-658 | Generator Control Module |
| P0A1A-659 | Generator Control Module |
| P0A1A-791 | Generator Control Module |
| P0A1B-163 | Drive Motor "A" Control Module |
| P0A1B-164 | Drive Motor "A" Control Module |
| P0A1B-192 | Drive Motor "A" Control Module |
| P0A1B-193 | Drive Motor "A" Control Module |
| P0A1B-198 | Drive Motor "A" Control Module |
| P0A1B-511 | Drive Motor "A" Control Module |
| P0A1B-512 | Drive Motor "A" Control Module |
| P0A1B-661 | Drive Motor "A" Control Module |
| P0A1B-786 | Drive Motor "A" Control Module |
| P0A1B-794 | Drive Motor "A" Control Module |
DESCRIPTION
The MG ECU located in the inverter with converter assembly monitors its internal operation and it will store DTCs when it detects malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A1A-151 | Generator Control Module | Run pulse signal cycle deviation or stop | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-155 | Generator Control Module | A/D converter error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-156 | Generator Control Module | CPU ROM-RAM error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-166 | Generator Control Module | R/D converter NM stop error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-658 | Generator Control Module | ALU error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-659 | Generator Control Module | Communication error (from MG1 to MG2) | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-791 | Generator Control Module | R/D converter communication error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-163 | Drive Motor "A" Control Module | IPM positive power source error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-164 | Drive Motor "A" Control Module | IPM negative power source error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-192 | Drive Motor "A" Control Module | A/D converter error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-193 | Drive Motor "A" Control Module | CPU ROM-RAM error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-198 | Drive Motor "A" Control Module | R/D converter NM stop error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-511 | Drive Motor "A" Control Module | Standard voltage for analog signal offset error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-512 | Drive Motor "A" Control Module | Standard voltage for analog signal error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-661 | Drive Motor "A" Control Module | Communication error (from MG2 to MG1) | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-786 | Drive Motor "A" Control Module | ALU error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-794 | Drive Motor "A" Control Module | R/D converter communication error | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A-155, 156, 166, 658, 791 | Generator Control Module |
| P0A1B-163, 164, 192, 193, 198, 511, 512, 661, 786, 794 | Drive Motor "A" Control Module |
Turn the power switch off.
| B |
|
REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS Click here |
| A |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART Click here |
| A |
|
CLEAR DTC
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY Click here |
| C |
|
GO TO DTC CHART Click here |
| A |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY
Check the part number of the inverter with converter assembly.
| Result | |||||||
|---|---|---|---|---|---|---|---|
|
| A |
|
REPLACE MG CONTROL COMPUTER AND INVERTER CURRENT SENSOR AND INVERTER WIRE |
| B |
|
REPLACE MG CONTROL COMPUTER |
CHECK INVERTER WITH CONVERTER ASSEMBLY
Check the part number of the inverter with converter assembly.
| Result | |||||||
|---|---|---|---|---|---|---|---|
|
| A |
|
REPLACE POWER MODULE INTELLIGENT TRANSISTOR KIT AND MG CONTROL COMPUTER AND INVERTER CURRENT SENSOR AND INVERTER WIRE |
| B |
|
REPLACE POWER MODULE INTELLIGENT TRANSISTOR KIT AND MG CONTROL COMPUTER |