FREEZE FRAME DATA
Tech Tips
The power management control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred. To confirm the details of the hybrid control system, check the detailed information for the DTC information code in the Data List (INF code).
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Select a DTC in order to display its freeze frame data.
Check the freeze frame information recorded with the DTC.
| Tester Display | Measurement Item | Range | Diagnostic Note |
|---|---|---|---|
| Engine Coolant Temp | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Cold or warmed-up engine |
| Engine Revolution | Engine speed | Min.: 0 rpm, Max.: 16383 rpm | Engine speed |
| Vehicle Spd | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) | Stopped, or driving (at low, medium, or high speeds) |
| Engine Run Time | Elapsed time after starting engine | Min.: 0 s, Max.: 65535 s | After the power switch is turned on (READY), elapsed time from initial engine start until the power switch is turned off. |
| +B | Auxiliary battery voltage | Min.: 0.00 V, Max.: 65.53 V | Auxiliary battery condition |
| Accel Pedal Pos #1 | Accelerator pedal position sensor No. 1 | Min.: 0.0%, Max.: 100.0% | Idling, accelerating, or decelerating |
| Accel Pedal Pos #2 | Accelerator pedal position sensor No. 2 | Min.: 0.0%, Max.: 100.0% | For comparison to accelerator pedal position sensor No. 1 |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Hot or cold weather |
| Intake Air Temperature | Intake air temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | Hot or cold weather |
| DTC Clear Warm Up | The number of times the engine is warmed up after clearing DTCs | Min.: 0, Max.: 255 | Frequency of malfunction recurrence after clearing DTCs |
| DTC Clear Run Distance | Drive distance after clearing DTCs | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | Frequency of malfunction recurrence after clearing DTCs |
| DTC Clear Min | Elapsed time after clearing DTCs | Min.: 0 min, Max.: 65535 min | Elapsed time after clearing DTCs |
| MAP | Intake manifold pressure | Min.: 0 kPa, Max.: 255 kPa | - |
| Atmosphere Pressure | Atmospheric pressure | Min.: 0 kPa, Max.: 255 kPa | Vehicle driving elevation |
| Ready Signal | Power switch condition | ON or OFF | - |
| Motor(MG2) Revolution | MG2 revolution | Min.: -32768 rpm, Max.: 32767 rpm | - |
| Motor(MG2) Torq | MG2 torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm | - |
| M(MG2) Trq Exec Val | MG2 torque execution value | Min.: -4096.00 Nm, Max.: 4095.87 Nm | - |
| Generator(MG1) Rev | MG1 revolution | Min.: -32768 rpm, Max.: 32767 rpm | - |
| Generator(MG1) Torq | MG1 torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm | - |
| G(MG1) Trq Exec Val | MG1 torque execution value | Min.: -4096.00 Nm, Max.: 4095.87 Nm | - |
| Regenerative Brake Torq | MG1 regenerative braking execution torque | Min.: -4096.0 Nm, Max.: 4095.0 Nm | - |
| Rqst Regen Brake Torq | Requested MG1 regenerative braking torque | Min.: -4096.0 Nm, Max.: 4095.0 Nm | - |
| Inverter Temp-(MG1) | Generator inverter temperature | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| Inverter Temp-(MG2) | Motor inverter temperature | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| Motor Temp No2 | MG1 temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Motor Temp No1 | MG2 temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Accelerator Degree | Accelerator pedal depressed angle | Min.: 0.0%, Max.: 100.0% | Idling, accelerating, or decelerating |
| Request Power | Request engine power | Min.: 0 W, Max.: 655350 W | - |
| Target Engine Rev | Target engine speed | Min.: 0 rpm, Max.: 65535 rpm | - |
| Total Distance Traveled | Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) | - |
| State of Charge (All Bat) | HV battery state of charge | Min.: 0.0%, Max.: 100.0% | State of charge of HV battery |
| Master Cylinder Ctrl Trq | Master cylinder control torque | Min.: -4096.0 Nm, Max.: 4095.0 Nm | Brake force requested by driver |
| Power Resource VB | HV battery voltage | Min.: 0.0 V, Max.: 6553.5 V | HV battery condition |
| Power Resource IB | HV battery current | Min.: -327.68 A, Max.:327.67 A | HV battery condition |
| Power Supply Sensor Voltage | Power supply sensor voltage (VC) | Min.: 0.00 V, Max.: 79.99 V | - |
| VL-Voltage before Boosting | High voltage before it is boosted | Min.: 0 V, Max.: 360 V | - |
| VH-Voltage after Boosting | High voltage after it is boosted | Min.: 0 V, Max.: 1000 V | - |
| Boost Ratio | Boost converter boost ratio | Min.: 0.0%, Max.: 127.5% | - |
| Drive Condition ID | Drive condition ID/
|
- | Engine operating condition |
| Shift Sensor Main | Shift sensor (Main) voltage | Min.: 0.00 V, Max.: 4.98 V | - |
| Shift Sensor Sub | Shift sensor (Sub) voltage | Min.: 0.00 V, Max.: 4.98 V | - |
| Shift Sensor Select Main | Select sensor (Main) voltage | Min.: 0.00 V, Max.: 4.98 V | - |
| Shift Sensor Select Sub | Select sensor (Sub) voltage | Min.: 0.00 V, Max.: 4.98 V | - |
| Shift Sensor Shift Pos | Shift position | P/R/N/D/B | Selected shift position |
| Crank Position | Crankshaft position | Min.: -128 deg (CA), Max.: 127 deg (CA) | - |
| A/C Consumption Pwr | A/C consumption power | Min.: 0 W, Max.: 12750 W | - |
| Short Wave Highest Val | Waveform voltage in leak detection circuit in battery voltage sensor | Min.: 0.00 V, Max.: 4.98 V | Electrical leakage presence |
| MG1 Control Mode | MG1 control mode | PWM: 0/Variable PWM: 1/Rectangular wave: 2 | Operating state of inverter with converter assembly |
| MG1 Carrier Frequency | MG1 carrier frequency | 0.75 kHz/1.25 kHz/2.50 kHz/3.75 kHz/5.00 kHz/10.00 kHz | Operating state of inverter with converter assembly |
| MG2 Control Mode | MG2 control mode | PWM: 0/Variable PWM: 1/Rectangular wave: 2 | Operating state of inverter with converter assembly |
| MG2 Carrier Frequency | MG2 carrier frequency | 0.75 kHz/1.25 kHz/2.50 kHz/3.75 kHz/5.00 kHz | Operating state of inverter with converter assembly |
| Num of Current Code | The number of current DTCs | Min.: 0, Max.: 255 | - |
| Num of History Code | The number of history DTCs | Min.: 0, Max.: 255 | - |
| Calculate Load | Calculated load | Min.: 0.0%, Max.: 100.0% | - |
| Throttle Position | Throttle position sensor | Min.: 0.0%, Max.: 100.0% | Idling, accelerating, or decelerating |
| DCDC Cnv Tar Pulse Duty | Target auxiliary battery voltage | Min.: 0.0%, Max.: 399.9% | Auxiliary battery condition |
| Inverter Coolant Water Temperature | Inverter coolant temperature | Min.: -40°C (-40°F), Max.: 110°C (230°F) | Hot or cold weather |
| Cooling Fan 0 | Cooling fan operating condition | Min.: 0.0%, Max.: 127.5% | Cooling fan operating condition |
| Cooling Fan Relay | BATT FAN relay | ON or OFF | Cooling fan operating condition |
| Inverter W/P Revolution | Inverter water pump assembly speed | Min.: 0 rpm, Max.: 15000 rpm | Operating state of inverter water pump assembly |
| Prohibit DC/DC conv sig | DC/DC converter prohibition signal | ON or OFF | Operating state of inverter with converter assembly |
| DC/DC Converter Status Voltage | DC/DC converter status voltage | Min.: 0.00 V, Max.: 4.99 V | - |
| EV Request | EV drive mode transition availability | ON or OFF | EV drive mode on or off |
| TRC OFF Switch | TRC OFF switch condition | OFF / TRC / TRC/VSC | VSC OFF switch on or off |
| Starter Switch | Starter ON/OFF signal | ON or OFF | - |
| Inv-T (MG1) aftr IG-ON | Generator inverter temperature soon after power switch on (IG) | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| Inv-T (MG2) aftr IG-ON | Motor inverter temperature soon after power switch on (IG) | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| Mtr-T (MG2) aftr IG-ON | MG2 temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Conv-Tmp after IG-ON | Boost converter temperature soon after power switch on (IG) | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| SOC after IG-ON | HV battery state of charge after power switch on (IG) | Min.: 0.0%, Max.: 127.5% | HV battery condition |
| Inv-Temp (MG1) Max | Generator inverter maximum temperature | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| Inv-Temp (MG2) Max | Motor inverter maximum temperature | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| Mtr-Temp (MG2) Max | MG2 maximum temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Converter Temp Max | Boost converter maximum temperature | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| Status of Charge Max | Maximum status of charge | Min.: 0.0%, Max.: 127.5% | HV battery condition |
| Status of Charge Min | Minimum status of charge | Min.: 0.0%, Max.: 127.5% | HV battery condition |
| Stop Light Switch | Stop light switch condition | ON or OFF | Brake pedal depressed |
| Auxiliary Batt Temperature | Auxiliary battery temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Collision Signal (Airbag) | Detection of collision by airbag sensor assembly | ON or OFF | Operating state of airbag sensor assembly |
| TC Terminal | TC terminal state | ON or OFF | - |
| Inter Lock Switch | Interlock switch condition | ON or OFF | Power switch on (IG), inverter cover, high voltage input cables or service plug grip not installed: ON |
| EV Switch | EV drive mode switch (combination switch assembly) condition | ON or OFF | EV drive mode switch on or off |
| Back Up Lamp Relay | Back up light switch condition | ON or OFF | Reverse (R) selected: ON |
| ECO Mode | ECO mode transition availability | ON or OFF | ECO mode on or off |
| Generate Torque | Generated drive torque | Min.: -4096.0 Nm, Max.: 4095.8 Nm | - |
| Prohibit Charge for P Pos | HV battery charge in park (P) selected prohibition state | ON or OFF | - |
| Vehicle Parking (T/M Ctrl) | Indicates whether vehicle being driven or stopped | ON or OFF | - |
| Shift Pos Status (T/M Ctrl) | Indicates whether park (P) is selected | Not P / Run / P | - |
| Shift P Permission Signal | Indicates whether selection of park (P) is permitted | ON or OFF | - |
| DC/DC Cnv Temp (Upper) | Boost converter temperature (upper) | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| Safing Signal (Airbag) | Safing state of the airbag sensor assembly | ON or OFF | Operating state of airbag sensor assembly |
| DC/DC Cnv Temp (Lower) | Boost converter temperature (lower) | Min.: 15°C (59°F), Max.: 150°C (302°F) | - |
| Normal Signal for A/B ECU | Control state of airbag sensor assembly | ON or OFF | Operating state of airbag sensor assembly |
| Mtr-T (MG1) aftr IG-ON | MG1 temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Mtr-Temp (MG1) Max | MG1 maximum temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - |
| Overvoltage Input to Conv | Boost converter overvoltage detection | ON or OFF | - |
| Overvoltage Input to Inv | Inverter overvoltage detection | ON or OFF | - |
| Emergency Shutdown | Inverter emergency shutdown | ON or OFF | Operating state of inverter with converter assembly |
| MG1 Inverter Shutdown | Generator inverter shutdown | ON or OFF | Operating state of inverter with converter assembly |
| MG1 Inverter Fail | Generator inverter failure | ON or OFF | Operating state of inverter with converter assembly |
| MG2 Inverter Shutdown | Motor inverter shutdown | ON or OFF | Operating state of inverter with converter assembly |
| MG2 Inverter Fail | Motor inverter failure | ON or OFF | Operating state of inverter with converter assembly |
| Conv Shutdown | Boost converter shutdown | ON or OFF | Operating state of inverter with converter assembly |
| Converter Fail | Boost converter failure | ON or OFF | Operating state of inverter with converter assembly |
| P Pos SW Terminal Vol | Indicates voltage at the P position switch terminal | Min.: 0.00 V, Max.: 4.98 V | - |
| Internal Shift Position | ECU internal shift position | P/R/N/D/B | Selected shift position |
| P Rq Malfunction (T/M Ctrl) | Indicates whether park (P) selection request is normal | Normal or Abnormal | - |
| P Request (T/M Ctrl) | Indicates whether selection of park (P) is requested | ON or OFF | - |
| T/M Control ECU State | Indicates the control condition of the transmission control ECU | Normal or Abnormal | - |
| T/M ECU Pulse Consec Err | Indicates consecutive communication errors with the transmission control ECU | Normal or Abnormal | - |
| T/M ECU Pulse Single Err | Indicates a single communication error with the transmission control ECU | Normal or Abnormal | - |
| HV Start Condition | Indicates the hybrid start condition | Norml / Pr A/C / Remote | - |
| W/P Run Control Duty | Inverter water pump assembly motor drive request duty | Min.: 0.00%, Max.: 100.00% | Operating state of inverter water pump assembly |
| Engine Stop Request | Engine stop request | Request or No | Engine operating conditions |
| Engine Idling Request | Engine idling request | Request or No | Engine operating conditions |
| Main Batt Charging Rqst | HV battery charging request | Request or No | HV battery condition |
| Aircon Request | Engine starting request from air conditioning amplifier assembly | Request or No | - |
| Engine Warming Up Rqst | Engine warm-up request | Request or No | Engine operating conditions |
| SMRP Status | Operating state of SMRP | ON or OFF | Cannot be confirmed using the GTS. Use an oscilloscope. |
| SMRB Status | Operating state of SMRB | ON or OFF | - |
| SMRG Status | Operating state of SMRG | ON or OFF | - |
| SMRP Control Status | Commanded state of SMRP | ON or OFF | Cannot be confirmed using the GTS. Use an oscilloscope. |
| SMRB Control Status | Commanded state of SMRB | ON or OFF | - |
| SMRG Control Status | Commanded state of SMRG | ON or OFF | - |
| MG1 Gate Status | MG1 gate status | ON or OFF | Operating state of inverter with converter assembly |
| MG2 Gate Status | MG2 gate status | ON or OFF | Operating state of inverter with converter assembly |
| Converter Gate Status | Boost converter gate status | ON or OFF | Operating state of inverter with converter assembly |
| Aircon Gate Status | While A/C inverter a being shut off | ON or OFF | Operating state of inverter with converter assembly |
| Converter Carrier Freq | Boost converter signal carrier frequency | 9.55 kHz/9.13 kHz/8.71 kHz/8.29 kHz/7.87 kHz/7.45 kHz/ 4.8 kHz | Operating state of inverter with converter assembly |
| Delta SOC | Difference between maximum and minimum values of SOC | Min.: 0.0%, Max.: 127.5% | SOC variance |
| Batt Pack Current Val | HV battery current | Min.: -327.68 A, Max.: 327.67 A | HV battery charge/discharge status
|
| Inhaling Air Temp | HV battery intake air temperature | Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) | - |
| Auxiliary Battery Vol | Auxiliary battery voltage | Min.: -40.00 V, Max.: 39.99 V | Auxiliary battery condition |
| Charge Control Value | Charge control wattage sent from battery voltage sensor to power management control ECU | Min.: -64.0 kW, Max.: 63.5 kW | Charge amount of HV battery |
| Discharge Control Value | Discharge control wattage sent from battery voltage sensor to power management control ECU | Min.: -64.0 kW, Max.: 63.5 kW | Discharge amount of HV battery |
| Cooling Fan Mode1 | Battery cooling blower assembly operation mode | Min.: 0, Max.: 6 | HV battery cooling fan activation condition
|
| Cooling Fan Frequency1 | Battery cooling blower assembly frequency | Min.: 0.0 Hz, Max.: 6553.5 Hz | Battery cooling blower assembly |
| ECU Control Mode | Battery control mode | Min.: 0, Max.: 4 | HV battery control status |
| Standby Blower Request | Battery cooling fan Lo speed requested | ON or OFF | Operating state of cooling fan |
| Temp of Batt TB1 | Battery module temperature | Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) | HV battery temperature |
| Temp of Batt TB2 | Battery module temperature | Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) | HV battery temperature |
| Temp of Batt TB3 | Battery module temperature | Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) | HV battery temperature |
| Battery Block Vol -V01 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V02 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V03 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V04 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V05 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V06 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V07 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V08 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V09 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V10 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V11 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V12 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V13 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Battery Block Vol -V14 | Battery block voltage | Min.: 0.00 V, Max.: 79.99 V | Each HV battery block voltage variance |
| Pattern Switch (PWR/M) | POWER mode transition availability | ON or OFF | - |
| Detail Code 1 | Number of detailed information stored by information code | Min.: 0, Max.: 32767 | - |
| Detail Code 2 | Number of detailed information stored by information code | Min.: 0, Max.: 32767 | - |
| Detail Code 3 | Number of detailed information stored by information code | Min.: 0, Max.: 32767 | - |
| Detail Code 4 | Number of detailed information stored by information code | Min.: 0, Max.: 32767 | - |
| Detail Code 5 | Number of detailed information stored by information code | Min.: 0, Max.: 32767 | - |
INFORMATION
Tech Tips
Similar to freeze frame data, the power management control ECU also records vehicle and driving condition information as Information (INF code) at the moment a DTC is stored.
Select the information item which has an INF code from among Information 1 to 5.
Check the information for the DTC.
| Tester Display | Measurement Item/Range | Suspected Vehicle Status When Malfunction Occurs |
|---|---|---|
| Information 1 to 5 | INF code | Identification of malfunctioning system |
| Generator(MG1) Rev |
|
MG1 speed
|
| Motor(MG2) Revolution |
|
MG2 speed
|
| Generator(MG1) Torq |
|
When MG1 rotates in "+" direction:
When MG1 rotates in "-" direction:
|
| Motor(MG2) Torq |
|
When MG2 rotates in "+" direction:
When MG2 rotates in "-" direction:
|
| Request Power |
|
Engine power output requested to ECM |
| Engine Spd |
|
Engine speed |
| Master Cylinder Ctrl Trq |
|
Brake force requested by driver |
| State of Charge |
|
Charge of amount HV battery |
| WOUT Control Power |
|
Discharge amount of HV battery |
| WIN Control Power |
|
Charge amount of HV battery |
| Drive Condition ID | Drive condition ID/
|
Engine operating condition |
| Power Resource VB |
|
HV battery voltage |
| Power Resource IB |
|
HV battery charge and discharge current
|
| Shift Sensor Shift Pos |
|
Shift lever position sensor |
| Auxiliary Batt Voltage |
|
Auxiliary battery condition |
| VL-Voltage before Boosting |
|
High voltage level before it is boosted |
| VH-Voltage after Boosting |
|
High voltage level after it is boosted |
| The Time of Ignition ON |
|
Time elapsed with power switch on (IG) |
| Vehicle Speed(Max) |
|
Maximum vehicle speed |
| Engine Stop Request |
|
Engine stop request |
| Engine Idling Request |
|
Idle stop request |
| Engine Fuel Cut |
|
Fuel cut |
| Main Batt Charging Rqst |
|
HV battery charging request |
| Engine Warming Up Rqst |
|
Engine warm-up request |
| Stop Switch |
|
Brake pedal depressed or released |
| Exclusive Information 1 |
|
Exclusive information linked to Information |
| Exclusive Information 2 |
|
Exclusive information linked to Information |
| Exclusive Information 3 |
|
Exclusive information linked to Information |
| Exclusive Information 4 |
|
Exclusive information linked to Information |
| Exclusive Information 5 |
|
Exclusive information linked to Information |
| Exclusive Information 6 |
|
Exclusive information linked to Information |
| Exclusive Information 7 |
|
Exclusive information linked to Information |
| Occurrence Order | Occurrence sequence of information | Occurrence sequence of information |
| Cnv Tmp (Upper) |
|
Boost converter temperature |
| Cnv Temp (Lower) |
|
Boost converter temperature |
| Generator Temp |
|
MG1 temperature |
| MG1 Carrier Frequency |
|
MG1 inverter carrier frequency |
| MG2 Carrier Frequency |
|
MG2 inverter carrier frequency |
| Motor Temp |
|
MG2 carrier temperature |
| Converter Carrier Freq |
|
Converter carrier frequency |
| Inverter Temp (MG1) |
|
Generator inverter temperature |
| MG1 Control Mode |
|
MG1 control mode |
| Inverter Temp (MG2) |
|
Motor inverter temperature |
| MG2 Control Mode |
|
MG2 control mode |
| Boost Ratio |
|
Boost condition |
| MG1 Inverter Shutdown |
|
Generator inverter shutdown: ON |
| HV Coolant Temperature |
|
HV coolant temperature |
| MG2 Inverter Shutdown |
|
Motor inverter shutdown: ON |
| Accel Sensor Main |
|
Idling, accelerating, or decelerating |
| Conv Shutdown |
|
Boost converter shutdown: ON |